My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
13430
>
2300 - Underground Storage Tank Program
>
PR0501287
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2022 2:41:13 PM
Creation date
11/5/2018 6:38:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0501287
PE
2381
FACILITY_ID
FA0005054
FACILITY_NAME
DELTA PUB & GROCERY
STREET_NUMBER
13430
Direction
N
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05807006
CURRENT_STATUS
02
SITE_LOCATION
13430 N LOWER SACRAMENTO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\L\LOWER SACRAMENTO\13410\PR0501287\BILLING 1985 - 1990.PDF
QuestysFileName
BILLING 1985 - 1990
QuestysRecordDate
7/31/2017 10:33:28 PM
QuestysRecordID
3538091
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION , <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING I FORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TAN <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> A) <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: G Cr FARM TANK-YES❑ NO I� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY D <br /> u <br /> A. OWNERS TANK ID# O B. MANUFACTURED BY: <br /> G YEAR INSTALLED D. TANK CAPACITY IN GALLONS: [ <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 OUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER E] 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 P NOLIC LINING <br /> C. INTERIOR <br /> LINING ❑ 5 GLASS LINING ❑6 UNLINED 95 KNOWN ' - A <br /> F-1ISLINING MATERIAL COMPATIBLE WITH I Do%MEFHANOL? ❑YES ❑ NO 99 OTHER ( �y(-/ <br /> D.CORROSION ❑ 1 POLYETHUENEWRAP ROR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMAkON CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE ASUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A SALUMINUM A U 6CONCRETE A U 7STEEL CLAD W/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> ' 1 <br /> PPA <br /> 1 VISUALCHECK S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> 1 P S 6 PRECISION TESTING P S 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED7 TE LAST USED IMO/YR) 2. ESTIMATE OUANTITYOF 3, WAS NK FILLED WITH <br /> SUBST E EMAINING INN IJIPTERIAL? El YES [:] NO <br /> GALLONS fy <br /> THIS F RM HAS BEEN COMPLETED UNDER PENALTY bFPERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> Q� U1 as IV <br /> CUIIRENT LOCAL A ENCY FACILITY ID# APP RONAME 7 PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PGE MIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(6-29-B8) THIS FORM MUST BE AM— ANTE A FACILITYI U APPLICATION, FORM `A',UNLESS A RENT FORM'A' HAS BEEN FILED ' <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.