My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
3550
>
2300 - Underground Storage Tank Program
>
PR0505827
>
COMPLIANCE INFO_1997-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:05:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2007
RECORD_ID
PR0505827
PE
2361
FACILITY_ID
FA0007030
FACILITY_NAME
VALLEY PACIFIC HWY 99 CARDLOCK
STREET_NUMBER
3550
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17916043
CURRENT_STATUS
01
SITE_LOCATION
3550 S HWY 99
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\3550\PR0505827\COMPLIANCE INFO 1997-2007.PDF
QuestysFileName
COMPLIANCE INFO 1997-2007
QuestysRecordDate
6/21/2017 4:01:59 PM
QuestysRecordID
3452124
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page S ofd_ <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: U Sump Manufacturer 81 Industry Standard U Professional Engineer <br /> U Other(Specify) <br /> Test Method Used: U Pressure U Vacuum X)Hydrostatic <br /> U Other(Sped) <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> Sump# 1 Reg Sump#2 Diese Sump# Sump# <br /> Sump Diameter: 4211 n <br /> Sump Depth: 52" 53" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: 1411 2011 <br /> Height from Tank Top to Lowest 18" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Clean/Dry Oily <br /> Portion of Sump Tested' 1 " 2211 <br /> Does turbine shut down when yes UNo UNA <br /> sump sensor detects either product ZIXYes UNo UNA UYes UNo UNA UYes UNo UNA <br /> or water? <br /> Turbine shutdown response time Z' 4 seconds 4 seconds <br /> Is system programmed for fail-safe XI Yes U No U NA <br /> shutdown?' IXYes UNo UNA UYes UNo UNA U Yes U No U NA <br /> Was fail-safe verified to be XI Yes UNo UNA <br /> operational?* lXYes IJNo UNA UYes UNo UNA UYes UNo UNA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 2 hr. z hr. <br /> test: <br /> Test Start Time: 10:00 1 1 •0 0 <br /> Initial Reading(R,): <br /> Test End Time: 10:30 1 1 3 0 <br /> Final Reading(R,): <br /> Test Duration: hr <br /> Change in Reading(Ry-R,): <br /> Pass/Fail Threshold or Criteria: Loss Q Loss <br /> Test Result: IX Pass U Fall UKPass U Fall U Pass U Fall U Pass U Fall <br /> Was sensor removed for testing? Xi Yes UNo UNA LXYcs U No UNA UYes UNo UNA UYes UNo UNA <br /> Was sensor properly replaced and Xl Yes U No U NA <br /> verified functional after testing? IXYes UNo UNA UYes UNo UNA UYes UNo UNA <br /> C0 Mmellts— (include in ormalion on repairs made prior to testing and recommended follow-up forfailed tests) <br /> If the testing method does not test the entire depth of the sump,specify how much of the sump was tested. Methods not testing the <br /> entire sump should only be used if the monitoring system provides fail-safe turbine shutdown. (See SWRCB LG-160) <br /> a With the submersible pump running,place the sensor in product(discriminating sensors should also be placed in water). The time <br /> between placing the sensor in product and the turbine shutting down is the response time. This should be done if the secondary <br /> containment testing method used does not test the entire volume of the sump. <br /> This information is not needed if the entire sump is tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.