Laserfiche WebLink
San Joaquin County DIRECTOR <br /> Donna Heran,REHS <br /> Environmental Health Department <br /> .p M ASSISTANT DIRECTOR <br /> 600 East Main Street Laurie Cotulla,REHS <br /> ht < < Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> Carl Borgman, REHS <br /> Cq• P.• <br /> Website: wwws OV.Or ehd Mike Huggins,REHS,RDI <br /> Wb <br /> �rFORt� Jg � Margaret Lagorio,REHS <br /> Phone: (209) 468-3420 Robert McClellon, REHS <br /> September 20, 2007 Fax: (209) 464-0138 KaseyJeff aFoley,R HSHS,RDI <br /> Elite IV Contractors, Inc. <br /> 2535 Wigwam Dr. <br /> Stockton, CA 95205 <br /> Re: Rapid Wash,3550 S. Hwy 99 Frontage,Rd.,Stockton, CA <br /> Your application for a permit(SR0051968)to replace the mechanical line leak detector and shear valve at the above <br /> referenced address has been received and approved with the following conditions: <br /> Conditions of approval: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits. <br /> 2. Any changes shall be submitted to EHD for approval prior to commencing work.All new addenda <br /> supercede the previous ones. <br /> 3. All components must be certified by an independent testing organization and labeled as required by the <br /> organization.(UL,ULC,ANSI,API,ASTM,etc. See California Code of Regulations(CCR),Title 23 <br /> Chapter 16 Table B for complete list). The component must bear the appropriate mark as required by the <br /> independent testing organization. <br /> 4. All monitoring equipment must be approved and listed in the State Water Resources Control Board's Local <br /> Guidance Letter 113:"List of Leak Detection Equipment and Methods for Underground Storage Tanks." <br /> 5. Qualified service technicians must possess or work under the direct and personal supervision of an <br /> individual physically present at the work site who possesses all of the following: <br /> a. One of several permissible valid,current contractor's licenses issued by the Contractors State <br /> License Board(may be issued to the installation company),and <br /> b. All valid,current California UST certificates issued by the International Code Council(ICC),that <br /> are applicable to the work being performed,and <br /> c. A valid,current certificate of training from the manufacturer(s)of the component(s)being tested, <br /> repaired,or serviced. <br /> 6. Each person installing or testing any component must hold a certificate of training from the manufacturer <br /> of that component. <br /> 7. Contact Ray von Flue(468-9848)to arrange the following inspection appointments(a 48-hour notice is <br /> required for inspection appointments): <br /> a. Verification of three gallon per hour leak test for Red Diesel line. <br /> b. Verification of float/chain mechanism operation with water. <br /> 8. A"Certificate of Compliance for Underground Storage Tank Installation Form C"shall be submitted by the <br /> owner or the owners'agent[pursuant to(CCR)2635(d)]before this upgrade will be considered complete <br /> by EHD. <br /> 9. This permit expires December 20,2007. <br /> If you have any questions or need to schedule an inspection,please contact me at(209)468-9848. <br /> Ray von Fide,REHS <br /> Senior Registered Environmental Health Specialist <br />