My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:14:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2012-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i� A 53/A 53M — 06a <br /> 0.04 in. <br /> t=specified well thlClmass 'MAx 1 <br /> DEPTH <br /> DEPTH <br /> 10%t,t 15% <br /> —\ I WITH MIN OF <br /> 0.012 10.002 in. <br /> it2�t [0.3* 0.05 mm] <br /> O1LESS <br /> LENGTH <br /> B (BUTTRESS) NOTCH FOR EDDY CURRENT-1.5 111.138mml MAX <br /> Total Lm4th <br /> 60° FOR DIVERTED FLUX <br /> �MAX--/ AND ULTRASONIC - 2 in. 150 n9ril MAX <br /> at Fun Death <br /> I. t NIO NOTCH <br /> Rt LESS <br /> VIO NOTCH <br /> r(3.2 mml <br /> 2 %t <br /> OLESS <br /> AREA OF EACH SIDE . 0.006 in 2[3.9 mmJ MAX <br /> P (PARALLEL SIDED) NOTCH DRILLED HOLE <br /> FIG. 1 Calibration Standards <br /> TABLE 3 Acceptance Limits imperfections or imperfections that extend an appreciable <br /> Type Notch Size of Hole Acceptance distance into the wall without complete penetration. <br /> Limit 9.22.6 A purchaser interested in ascertaining the nature <br /> in. mm Signal,% <br /> N10,VIO '/. 3.2 100 (type,size, location, and orientation) Of imperfections that are <br /> B P 80 capable of being detected in the specific application of these <br /> examinations is directed to discuss this with the manufacturer <br /> of the tubular product. <br /> 9.2.3 For ultrasonic testing, the calibration reference <br /> 9.2.2.1 The calibration standards defined in 92.3 through notches shall be at the option of the manufacturer,and shall be <br /> 92.5 are convenient standards for calibration of nondestructive any one of the three common notch shapes shown in Practice <br /> testing equipment.The dimensions of such standards are not to E 213. The depth of notch shall not exceed 12.5% of the <br /> be construed as the minimum sizes of imperfections detectable specified wall thickness of the pipe or 0.004 in. [0.1 mm], <br /> by such equipment. whichever is the greater. <br /> 9.2.2.2 The ultrasonic testing referred to in this specification 9.2.4 For eddy current testing, the calibration pipe shall <br /> is capable of detecting the presence and location of significant contain, at the option of the manufacturer, any one of the <br /> longitudinally or circumferentially oriented imperfections; following calibration standards to establish a minimum sensi- <br /> however, different techniques Heed to be employed for the tivity level for rejection. <br /> detection of differently oriented imperfections. Ultrasonic test- 9.2.4.1 Drilled Hole—The calibration pipe shall contain <br /> ing is not necessarily capable of detecting short, deep imper- three holes spaced 120° apart or four holes spaced 90° apart, <br /> fections. sufficiently separated longitudinally to ensure separately dis- <br /> 9.2.2.3 The eddy current examination referenced in this tinguishable responses.The holes shall be drilled radially and <br /> specification has the capability of detecting significant discon- completely through the pipe wall, care being taken to avoid <br /> tinuities, especially of the short abrupt type. distortion of the pipe while drilling. Dependent upon the <br /> 9.2.2.4 The flux leakage examination referred to in this nominal pipe size, the calibration pipe shall contain the <br /> specification is capable of detecting the presence and location following hole: <br /> of significant longitudinally or transversely oriented disconti- <br /> nuities. The provisions of this specification only require s,h SIS 0.039 in.[1.0 mml <br /> longitudinal calibration for flux leakage. Different techniques ,h A 1w >15 s 32 0.055 in.11.4 mml <br /> need to be employed for the detection of differently oriented >I i,2 >32,50 0.071 in.11.8 mml <br /> >2 s 5 >50 s 125 0.087 in.12.2 mml <br /> imperfections_ '5 >125 0.106 in.12.7 mml <br /> 9.2.25 The hydrostatic test referred to in 8.2 has the <br /> capability of finding imperfections of a size permitting the test 9.2.4.2 Transverse Tangential Notch—Using a round tool or <br /> fluid to leak through the tube wall and may be either visually file with a 1/4 in. [6 mm] diameter, a notch shall be filed or <br /> seen or detected by a loss of pressure.Hydrostatic testing is not milled tangential to the surface and transverse to the longitu- <br /> necessarily capable of detecting very tight through-the-wall dinal axis of the pipe. The notch shall have a depth not <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.