Laserfiche WebLink
A 53/A 53M - 06a <br /> TABLE X2.2 Continued <br /> SpecifiedSpecified Nominal Weight(Me") <br /> Outside NPS ON Oututside <br /> Designator Designator Diameter, Wall Thickness, per Unit Length,Plain Weight Class Schedule No. Test Pwsswe,^psi Ikea] <br /> in.lmml in.[mm] End,IWff(kg/m] <br /> Grade A Grade 8 <br /> 0.375[9.52] 78.67(117.021 STD 20 680[47001 790(54001 <br /> 0.406[10.311 84,04(12653) ... ... 730[5000] 650[59001 <br /> 0.436[11.131 91591136.37] ... ... 790(54001 920[6300) <br /> 0.469(11.911 97.92[145.70] 850[5900] 950[6500] <br /> 0.500[12.701 104.231155.12) XS 30 900162001 1050[7200] <br /> 0.594[15.09] 123.23[183.421 ... 40 1170[81001 1250(86001 <br /> 0.812[20.621 166.56[247.831 - 60 1460(10 1001 1710(11 8001 <br /> 1.031(26.191 209.06[311.17) ... 80 1860112 8001 2170(15 000) <br /> 1.281[32.54] 256.34[381.53] ... 100 2310[15 9001 2690(18 500] <br /> 1.500(38.101 296.65[441.49) ... 120 2700[18 6001 2800118 300] <br /> 1.750(44.451 341.41 [508.111 ... 140 2800[19 3001 2800119 3001 <br /> 1.969[50.011 379.53[564.811 ... 160 2800[19 3001 2800[19 3001 <br /> 24 600 24.000[6101 0250[6.351 63.47(94.46) ... to 380[2600] 440[30001 <br /> 0.281(7.141 71.25[106.081 ... ... 420[29001 490[3400] <br /> 0.312[7.92] 79.01[117.51) ... ... 470[3200] 550[38001 <br /> 0.344[8.741 86.99[129.501 520[36001 600141001 <br /> 0.375[9.521 94.71(140.881 STD 20 560[3900] 660f45001 <br /> 0.406(10.311 102.40[152.371 ... ... 610[42001 710(49001 <br /> 0.438(11.131 110.321164.261 .. ... 660[4500) 770(53001 <br /> 0.469[11.911 117.98[775.54] ... 700(48001 820(57001 <br /> 0.500(12.701 125.61(186.941 XS 750[5200] 880[6100) <br /> 0.562[14.27] 140.81(209.501 ... 30 840[5800] 980(6800] <br /> 0.688(17.48] 171.451265.241 ... 40 1030[7100] 1200(83001 <br /> 0.938(23.831 231.25[344.23) ... 1410[9700] 1640[11 3001 <br /> 0.969(24.611 238.57(355.02) ... 60 1450(10 000) 1700(11 700] <br /> 1.219(30.961 296.861441.78) ... 80 1830[12 6001 2130(14 700] <br /> 1.531[38.891 367.74[547.331 --- 100 2300[15 9001 2680(18 500) <br /> 1.812(46.02) 429.79[639.58) ... 120 2720118 8001 2800(19 300] <br /> 2.062(52.371 483.57[719.631 ... 140 2800(19 3001 2800119 3001 <br /> 2.344 159.541 542.641807.631 ... 160 2600(19 3001 2800[19 3001 <br /> 26 650 26.000[6601 0.25016.351 68.82[102.421 • 350(24001 400(2800] <br /> 0.281[7.141 77.26[115.021 ... 390127001 450(3100) <br /> 0.312[7.921 85.68[127.431 10 430130001 500[34001 <br /> 0.344[8.741 94.35[140.451 ... 480[33001 560(3900] <br /> 0.375[9.521 102.72[152.801 STD ... 520[36001 610(42001 <br /> 0.406[10.31] 111.08(165.281 560[39001 660145001 <br /> 0.438(11.131 119.69(178.201 ... 610[4200) 710[49001 <br /> 0,489[11.911 126.001190.46] 650(45001 760[52001 <br /> 0.500(72.70) 136.30(202.85] XS 20 690[4800) 810[56001 <br /> 0.562[14.271 152.83[227.371 ... ... 780(54001 910[63001 <br /> ^The minimum last pressure for outside diameters and wall thicknesses not listed shall be computed by the formula given below.The computed test pressure shall be <br /> used in all cases,except as follows: <br /> (1) For specified wall thicknesses greater than the heaviest specified wall thickness listed in this table for the applicable specified outside diameter.the test pressure <br /> shall be the highest value listed for the applicable specified outside diameter and grade. <br /> (2) For pipe smaller tram NPS 21DN 501 with a specified wall thickness less than the lightest specified wall thickness listed in this table for the applicable specified outside <br /> diameter and grade. <br /> (3) For all sizes of Grade A and B pipe smaller than NPS 2(DN 501,the last pressures were assigned aromadly.Test pressures for intermediate specified outside <br /> diameters need not exceed those given in this table for the next larger listed size. <br /> P=2SYD <br /> where: <br /> P = minimum hydrostatic test pressure,psi[kPa], <br /> S = 0.60 times the specified minimum yield strength,psi(kPal, <br /> t = specified wall thickness,in.[mml,and <br /> D = specified outside diameter,in.[mm). <br /> IS <br />