My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:14:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2012-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCH ARCO AM PM* 4855 S HWY 99 EAST FRONTAGE RD, November 25, 2014 <br /> j SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS it,or MINOR-Notice to Comply) ; <br /> Item# Remarks <br /> 126 HSC 25404(e)(4) Failed to report program data electronically. <br /> A submission to the California Electronic Reporting System (CERS)for the underground storage tank(UST) program is <br /> not complete. Beginning January 1, 2014, all businesses are required to submit all new(or any changes to existing) <br /> UST information, including: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response <br /> Plan, UST Owner/Operator Written Agreement(if applicable), UST Letter from Chief Financial Officer, and Owner <br /> Statement of Designated UST Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure to <br /> include any other relevant activities and required fields. This is a minor violation. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance records for the 87 Fill Sump fuel alarms on 02/07/2014 and 06/14/2014 were not found on site. These <br /> records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of all <br /> monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br /> observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on site <br /> and submit copies to the EHD. This is a minor violation. <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br /> The March 2014 designated operator monthly inspection reports were not found on site. Designated operator monthly <br /> inspection reports for the previous twelve months shall be retained on site. Locate and ensure that copies of the <br /> previous twelve months of designated operator monthly inspection reports are maintained on site. Submit copies to the <br /> EHD. This is Class II repeat violation. <br /> 319 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Approximately a gallon of liquid was observed in the 87.fill sump, and 2 to 4 cups of liquid in each of the 89 STP sump <br /> and 91 STP sump. If water could enter into the secondary containment by precipitation or infiltration, it must be <br /> removed and disposed of properly. The service technician removed liquid from all three sumps and disposed to the <br /> hazardous waste drum onsite. Ensure that all sumps and annular spaces are maintained free of liquid. This is a Class <br /> II repeat violation; this violation has been corrected onsite. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 12/31/2014. <br /> Consent to perform the inspection, take photos and collect samples was given by Nima Badial, General Manager <br /> and compliance officer. This report has been mailed to owner on 11/26/2014 after the inspection due to <br /> equipment technical difficulties. <br /> This facility's designated operator is Guadalupe Sanchez ICC expiration date: 02/09/2015. The service <br /> technician was Guadalupe Sanchez ICC expiration date: 04/20/2015 , who had the following manufacturer's <br /> certifications: VR 11/07/2015; VMI 05/1212015 . <br /> Received by(initial): Inspector: Phone: Date: <br /> JEFFREY WONG, Senior REHS (209)468-0335 11/25/2014 <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.