My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:14:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2012-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONI01UNG SYSTEM CERTIARATION RECEIVED <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code tq,j,&R¢ulgtigns'13 <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control Panel by the technician who performs the work. A copy of this form must be provided tott dlhuf/ QerLTH <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test a[ePERMIT/SERVICES <br /> A. General Information <br /> Facility Name: ARCO Bldg.No.: <br /> Site Address: 4855 S. State Route 9 City: Stockton, Ca. Zip: 95215 <br /> Facility Contact Person: Gill Contact Phone No.: (209) 481-7445 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 11/1912013 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: 87 TanklD: 89 <br /> Z In-Tank Gauging Probe. Model: 847390-109 Z In-Tank Gauging Probe. Model: 847390-109 <br /> Z Annular Space or Vault Sensor. Model: 794390-407 Z Annular Space or Vault Sensor. Model: 794390-407 <br /> Z Piping Sump/Trench Sensor(s). Model: 794380-323 Z Piping Sump/Trench Seasons). Model: 794380-323 <br /> Z Fill Sump Sensor(s). Model: 794380-344 Z Fill Sump Seasons). Model: 794380-323 <br /> ❑Mechanical Line Leak Detector. Model: Z Mechanical Line Leak Detector. Model: 99LD-2000 <br /> Z Electronic Line Leak Detector. Model: RJ 244-006-5 ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> TanklD: 91 TanklD: <br /> Z In-Tank Gauging Probe. Model: 847390.109 ❑In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor. Model: 794390.407 ❑Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model: 794380-323 ❑Piping Sump/Trench Sensor(s). Model: <br /> Z Fill Sump Sensor(s). Model: 794380-323 ❑Fill Sump Seasons). Model: <br /> Z Mechanical Line Leak Detector. Model: 99LD-2000 ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: <br /> [-]Tank Overfill/High-Level Sensor. Model: E] 8h <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1&2 Dispenser ID: 38,4 <br /> Z Dispenser Containment Sensor(s). Model: 794380-323 Z Dispenser Containment Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: 58,6 Dispenser ID: 78,8 <br /> Z Dispenser Containment Sensor(s). Model: 794380-323 Z Dispenser Containment Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Cham(s). <br /> Dispenser ID: 98,10; 11&12 Dispenser ID: 13&14; 158,16; 17&18 <br /> Z Dispenser Containment Seasons). Model: 794380-323 Z Dispenser Containment Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑ Dispenser Containment Floats)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report; (check all that apply): ® System set-up ® Alarm istory report <br /> Technician Name(print): Guadalupe Sanchez Signatu -- cal <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services, Inc. Phone No.:(209) 845-8586 <br /> Testing Company Address: 11930 Horseshoe Rd, Oakdale,Ca. 95361 Date of Testing/Servicing: 11119/2013 <br /> Page 1 of 4 <br /> Rev(2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.