My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:13 PM
Creation date
11/5/2018 8:14:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2012-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dec 1713 05:44a Reliable Petroleum 2098458953 p.3 <br /> 12/17/2013 S:1SAN FAX 925233 Guadalupe Sanchez • goon/0016 <br /> Monitoring System Certification RECEIVE <br /> A. Results of Testing/Servicing <br /> DEC 17 2013 <br /> Software Version Installed: 329.01. <br /> ENVIRONMENTAL <br /> Co lett the following checklist: HEALTH DEPARTMENT <br /> ® Yes ❑ No* Is the audible alarm operational? <br /> E Yes ❑ No* Is the visual alarm opemfionaV <br /> ® Yes ❑ No* Were all sensors visually inspected,fuuotionaAy tested,and confirmed operatiorad? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes Q No* If alarms are relayed W a remote monitoring <br /> ® N/A operational? stab is all cftmmunicatons equipment (c g., modem) <br /> ® Yes —6-N-70-- <br /> 0 <br /> No*❑ NIA monitoring system detects a leak, !ails to operate,or is electrically disconneued? If yea: which sensors initiate <br /> positive shutdown? (Check all that apply) ® SutnplTrench Sensors; ®Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks end sensor failure/disconnection? ® Yes; ❑No. <br /> ® Yes ❑ NO Far tank sysmms that utilize the monitoring system as the primary tank overfill warning device (i.e, no <br /> ❑ N/A mechanical overfill prevention valve is installed), is the overfi(I waroitrg alarm visible and audible at the tank <br /> L11 points)and ape sting properly? If so,at what pcTcent of tank capacity does iha alarm trigge? 80% <br /> 21 Yes* ❑ No Was any monitor ng equipment replaced? If yes, identify spec sensors, probes,or other equipment replaced <br /> and list the manufacturer name end model for ail replacement parts in Section E,below. <br /> ❑ Yes* H No Was liquid found inside any secondary containment systems designed as dry systems? rCheck all that apply) <br /> ❑Product; ❑Water, If yes,describe causes in Section E,below. <br /> 0 Yes ❑ No` Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> 14 Yes ❑ No* fs all monitoring equipment operational per manufacturer's specifications? <br /> 'In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Replaced mechanical leek detector on the 89 STP.Model VMI 99 1-D-200,Serial#13101004. <br /> Inspector Stacy <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.