My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_2008-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
BILLING_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:50:43 PM
Creation date
11/5/2018 8:14:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2008-2012
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\BILLING 2008-2012.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 oft) <br /> VL UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD po-ser <br /> 1.CONTINUOUS ELECTRONIC MONITORING ❑ 2-FLOAT AND CHAIN ASSEMBLY 090-sem <br /> a.NO DISPENSERS 99.OTHERS ❑ 3.ELECTRONIC STAND-ALONE <br /> PANEL MANUFACTURER—^ _--- ...._—,....__.—.. ...................__. <br /> M_:_ <br /> LEAK SENSOR MANUFACTURER: �� ,� __--'- aiMODPI. <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ) 3 -ss <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN a O &YES ❑b.NO °ro'p <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN e'YES ❑b.NO mos <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. a.YES O 6.NO <br /> 2 UDC COif$TRUCTION IS tet.SINGLE-WALLED e.YES ❑b.NO °9osz <br /> .Nat ❑2.DOUBLE-WALLED ayo,D <br /> IF DOUBLE WALLED: <br /> UDC INTERSTITIAL SPACE IS MONITORED BYE-fel,LIQUID _�PRESSURE �VACUUM °"° <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND RMS VISUAL ALA '"�,YES ❑b.NO <br /> Val.PERIODIC SYSTEM TESTING <br /> I. ELD TESTING: THIS FACILITY HAS BEEN NOTiF1E0 BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHA NCFD a9oac. <br /> DETFCt70N fF1�D1 MUST BE PERFORMED._PERIObIC ELD IS PERFORMED EVERY 36 MONTHS AS, E IJI .(27 CCR g260d,IL_m <br /> -SF.CONDARV CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. <br /> 3.SPILL.ROCKETS ARE TESTED ANNUALLY. _---- —' .--•-_— _— ._490 <br /> 49047 <br /> The fallowing monitonrtg/rtlaintenmTa records am kept for this(kcil'tyL RECORDKEEPING <br /> e Almm logs woes, (3Visual Inspection Records 490e41, <br /> SIR testing results and supporting ❑Tank igauging moltestt,nails posse <br /> ${ 8 ( Pponing documentation records). °9o.oed ❑ Tank gauging results(end slrQ ni <br /> ATG Testing msults land Supporting documentation records).Aw of C] Prptection bp.day l <br /> Corrosion P° ng dowmen(atioo records)_ wo6ss <br /> ags 4931.4EQuipment meintgtanee and calibration Cards. °9afilh <br /> IX.TRAINING <br /> JK parsomwl with UST monitoring maponsibilmes ere familiar with All of the following docmtrents relevant w theirjob duties, waear <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)JIOPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)49as9c <br /> 1:1CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONSEl CALIFweeps <br /> UNDERGROUND STORAGE TANK LAW 4". <br /> ❑ STATE <br /> OWIITER RESOURCES RES CONTROL BOARD (SW CB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"°9os9r <br /> ❑ SWRCB PUBLICATTON:'IMERSTANDING AUTOMATTC TANK GAUGING SYSTEMS",,"ca <br /> b ❑ OTHER(Specify):htasq Nara <br /> ff�This facility hes a"Desigtuted USi t pt It I who has passed the 1 11 Nf tnia UST System Operator Exam administered by the)ntettgtiortal Code Council(ICC)- <br /> The"Dpigutmad UST Operator"will train facility omployees in the proper operation and maimenance of me UST systema annually,and within C <br /> touring will include but Is not limited to,the following' days of hire.This <br /> > Operation of the UST systems in a manner consistent with the fociliry'S best to, practiws <br /> > The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> > The facility employee's role with regard to spills and ov"Rlls as specified In the UST R <br /> I. Namara ofcartuct person(s)for emergencies and monog almms.°so->onito - esponsa Plan <br /> Provide additional commentX. COMMENTS/ADDITIONAL INFORMATION <br /> s here or indicate how many pages with additional information on spcci Tic matimring procedures are aetnched Ulis pl .aap-rt <br /> Orce�r�/t� bL. : A+r4'Ibdfsva a ►4k1 Q•~ S> � q 4� <br /> Xl.PERSONNEL RESPONSIBILITIES <br /> The UST Owrc,2)AB tvr is responsible for ensuring that: q the daily/routine UST monitoring activities and maintenance of UST Icak deTeation equipmem covered by <br /> Thu plan occurs,2)all conditiotn that indicate a possible release gra imesd <br /> The followi pn �and 3)dl monitoring records are maimained properly. <br /> AME /r(�' a Sasppnsiblc for pertormmg the monitoring end equipmem maim c <br /> /Y7�P •,'an TITLEy /Ff" //vCh hl�'r",� <br /> NAME (� w67e TITLE sso.n <br /> The Designated Operator shal perform a no thly visual i100 of the facility, provide a m %'i <br /> cwditions that need follow-up Action, <br /> to the owner/operator, and inform the owner/operator of airy <br /> X11.OWNER/OPERATOR SIGNATURE <br /> CERTIBICA ON:I certi that informatioll vided herein iS true and stet tato to the best of m tepowtedge- <br /> APPLICANTSI 'ATO <br /> wp)e DATE: 49.1 <br /> APPLICANT NAME(prinq: ., e9o.78 <br /> APP IJ CANT TITLE: uw-19 <br /> UPCF USTI(12/2007)3/4 rte'' <br />