My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:15:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 1998-2003.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
by • <br /> .1'6100 BP WEST AST PRODUCTS LLC <br /> MECHANICAL LEAK DETECTOR TEST DATA SHEET <br /> Station# 7�3 J O Date Z'� _ 20 Q� <br /> Address `9�f <br /> TEST INFORMATION <br /> 1 2 3 4 5 <br /> Product <br /> Manufacturer VA4 V,4-7 LlI/Al L//41 <br /> Model o&v L 19a20&0 zoaw L�M&,O <br /> Full Operating Pressure (psi) p;2 J 2- 7 <br /> Line Bleed Back(ml) / Sr /->r <br /> Trip Time (sec) 3 <br /> Metering Pressure (psi) / 02 � <br /> F/E Holding Pressure (psi) oC;2 & .241 <br /> Test Leak Rate (ml/min) (gph) �f �j' /Oc 8 <5 <br /> PASS or FAIL F,*Iz- rAIZ, PX /j /2 <br /> Replaced All Failed Leak Detectors Yes—X— No N/A <br /> If No, Replacement To Be Completed By (Date) —J-----J- <br /> This <br /> /This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the <br /> equipment manufacturer's procedures and limitations and the results as listed are to my knowledge true and correct. <br /> The mechanical leak detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br /> Inspected By: Contractor F1yL11 1V,.44E��j� ''�-S <br /> Technician Gr ar jx�� Lic# <br /> Signature <br /> APC3325 (9/02) <br />
The URL can be used to link to this page
Your browser does not support the video tag.