My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
INSTALL_1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:30 PM
Creation date
11/5/2018 8:16:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1997
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4855\PR0506650\1997 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />TANK DIAMETER <br />(FT.) <br />DEADMAN DIMENSIONS <br />(W x D) (IN.) <br />SLAB WIDTH <br />(FT.) <br />4 <br />6"x6" <br />6' <br />6 <br />12" x 12" <br />9.5' <br />8 <br />12"02" 12" <br />11' <br />10 <br />18" x 12" <br />13.5' <br />12 <br />36" x 8" <br />15' <br />TABLE 7-1 <br />FIGURE 7-1 <br />FIGURE 7-1A <br />Lay the deadmen in the excavation parallel to the tank'and <br />outside of the tank "shadow." (See Figure 7-1 and 7.1 A). In <br />multiple tank installations, each tank will require two deadmen. <br />The minimum spacing between tanks must be equal to twice the <br />width of a single deadman. One deadman may be used between <br />two tanks if it is doubled in width. Provide a separate anchor point <br />for each holddown strap. <br />ANCHOR SLAB <br />An anchor slab is a reinforced concrete base. The total length of <br />the slab must be at least the same as the tank. The minimum slab <br />thickness is 8 inches. The width of the slab depends on the tank <br />diameter. Refer to Table 7-1 for specific dimensions. Refer to Table <br />7.2 and Figure 7-2 for anchor point dimensions. Provide a separate <br />anchor point for each holddown strap. When using a concrete base <br />slab, allow sufficient depth in the excavation for 12 inches of <br />bedding material below the tank. (Figure 7-3). <br />0 <br />TABLE 7.2 <br />FIGURE 7-2 <br />FIGURE 7-3 <br />HOLDDOWN STRAPS <br />Xerxes FRP straps must be used when a tank is to be anchored <br />The location of holddown straps for each tank is marked on the <br />tank by the arrow (><) symbol. Complete data for holddown <br />straps are given in Table 7-2 and Figure 7.2. <br />Q CAUTION: <br />Place the straps only in the locations designated by the arrow <br />symbol (><). <br />To evenly distribute buoyancy loads, tighten all holddown straps <br />uniformly until they are snug over the ribs but cause no deflection <br />of the tank. Make an intermediate measurement of the tank <br />diameter AFTER the straps have been installed and tightened. <br />ANCHORING DIMENSIONS <br />TANK <br />DIAMETER <br />"A" <br />"B" <br />"C" <br />. E, <br />"D" <br />MIN. I MAX. <br />4' <br />24" <br />18" <br />12" <br />27" 30" <br />8'- 41/4" <br />6' <br />35" <br />23" <br />13" <br />42' 48" <br />12'-1" <br />8' <br />43" <br />31" <br />15" <br />52" 58" <br />15'-1" <br />10' <br />57" <br />45" <br />15" <br />69" 75" <br />18'- 83/4" <br />12' <br />1 58" <br />50" 1 <br />23" <br />87" 93" <br />22'- 63/4" <br />TABLE 7.2 <br />FIGURE 7-2 <br />FIGURE 7-3 <br />HOLDDOWN STRAPS <br />Xerxes FRP straps must be used when a tank is to be anchored <br />The location of holddown straps for each tank is marked on the <br />tank by the arrow (><) symbol. Complete data for holddown <br />straps are given in Table 7-2 and Figure 7.2. <br />Q CAUTION: <br />Place the straps only in the locations designated by the arrow <br />symbol (><). <br />To evenly distribute buoyancy loads, tighten all holddown straps <br />uniformly until they are snug over the ribs but cause no deflection <br />of the tank. Make an intermediate measurement of the tank <br />diameter AFTER the straps have been installed and tightened. <br />
The URL can be used to link to this page
Your browser does not support the video tag.