MONITCWING SYSTEM CERTIFOATION <br /> CERTIFICATION /TEST DATE: March 5, 2010 <br /> [Al. . OWNER <br /> Name 7-Eleven Market#23681 Store#32190 Name 7-Eleven, Inc <br /> Address 4943 South State Route 99,Stockton,CA 95206 Address P.O.Box 711,Dallas,TX 75221 <br /> Phone# 209-939-0679 Phone# 805-523-2949 <br /> Contact Jay Stemley Contact Jay Stemley <br /> D. RESULTS OF TESTING /SERVICING <br /> Make / Model of Monitoring System: Veeder-Root TLS-350 <br /> Software Version Installed: 329.02 <br /> Complete the following checklist: <br /> ■ Yes ❑ No* Is the audible alarm operational? <br /> ■ Yes ❑ No- Is the visual alarm operational? <br /> ■ Yes ❑ No• Were all sensors visually Inspected,functionally tested,and confirmed operational? <br /> ■ Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation? <br /> ■ Yes ❑ No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modems) <br /> ❑ NIA operational? <br /> ■ Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ NIA monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors Initiate <br /> positive shutdown? (check all that apply) ■ Sump/Trench sensors; ■ Dispenser Containment Sensors. <br /> ■ Yes ❑ No* Did you confirm positive shut-down due to leaks and sensor failure/disconnection? <br /> ❑ Yes ❑ No- For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> ■ NIA mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank <br /> fill <br /> point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? <br /> ❑ Yes• ■ No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ■ Yes` ❑ No Was any liquid found inside any secondary containment systems designed as dry systems? <br /> (Check all that apply) ❑ Product; ■ Water. If yes,describe causes in Section E,below. <br /> ■ Yes ❑ No* Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports,if applicable. <br /> ■ Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below, describe how and when these deficiencies were or will be corrected. <br /> E. COMMENTS <br /> A small amount of water was found in the 87 and 91 STP sump. <br /> The water was removed and left in owner supplied drum. <br /> cal law,- <br /> ©2006 Walton Engineering,Inc. <br /> Page 2 of 3 <br />