My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:17:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2012
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2010-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT�ING SYSTEM CE:RTIFWATION <br /> MAKE / MODE OF MONITORING SYSTEM: Veeder-Root TLS-350 <br /> CERTIFICATION / TEST DATE: October 17, 2011 <br /> Al. FACILITY A2. OWNER <br /> Name 7-Eleven Market#23681 Store#32190 Name 7-Eleven, Inc <br /> Address 4943 South State Route 99,Stockton,CA 95206 Address P.O.Box 711,Dallas,TX 75221 <br /> Phone# 209-939-0679 Phone# 805-523-2949 <br /> Contact Stephen Boyd Contact Stephen Boyd <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E.Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified October 11,2011 Lic# 617238 A,B, Haz <br /> Inspector Muniappa Naidu Contact Dulcinea Covan <br /> Phone# 209-468-8257 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> B1: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-89 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794380-303 ■ Annular Space or Vault Sensor Model: 0794380-303 <br /> ■ Piping Sump I Trench Sensors) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 _ <br /> ■ Fill Sump Sensors) Model: 0794380-208 ■ Fill Sump Sensor(s) Model: 0794380-208 <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ■ Electronic Line Leak Detector Model: 0848480-001 ■ Electronic Line Leak Detector Model: 0848480-009 <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Gasoline-91 Tank#4 (Product): <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794380-303 ❑ Annular Space or Vault Sensor Model: <br /> ■ Piping Sump/Trench Sensors) Model: 0794380.208 ❑ Piping Sump/Trench Sensors) Model: <br /> ■ FIII Sump Sensor(s) Model: 0794380-208 ❑ Fill Sump Sensors)l Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ■ Electronic Line Leak Detector Model: 0948480-001 ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> E12: DISPENSERS/UDC's <br /> Dispenser#: 1-2 Dispenser#: 3-4 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380.208 ■ Dispenser Containment Sensors) Model: 0794360-208 <br /> ■ Shear Valves ■ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chains) L❑ Dispenser Containment Float(s)and Chains) - - <br /> Dispenser#: 5-6 Dis7Dispenser <br /> 7-8 <br /> ■ Dispenser Containment Sensors) Model: 0794380-208 ■ ent Sensors) Model: 0794380-208 <br /> ■ Shear Valves ■ <br /> ❑ Dispenser Containment Float(e)and Chains) ❑ ent Float(s)and Chains) <br /> Dispenser#: 9-10 Dispenser#: 11-12 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380.208 ■ Dispenser Containment Sensors) Model: 0794380-208 <br /> ■ Shear Valves ■ Shear Valves <br /> ❑ Dispenser Containment Floats)and Chalri ❑ Dispenser Containment Floats)and Chahl <br /> C. CERTIFICATION I certify that the equipment Identified in this document was inspected/serviced In accordance with the manufacturers'guidelines. <br /> Attached to this Certification is Information(e.g.manufacturers'checklists)necessary to verity that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-UP ■ Alarm History Report <br /> WALTox <br /> Signature: ENGINEERING,INC. <br /> Technician/Cert#: Jessie Watkins/B35391 5307886-UT Date: October 17,2011 <br /> 0 2011 Walton Engineering,Inc. <br />