My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2008-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:17:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2009
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2008-2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
300
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> i Tanknology <br /> TEST DATE:12/01/09 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER2270669 <br /> CLIENT:7-ELEVEN, INC. AUSTIN,TEXAS 78759(512)451-6334 SITE:7-ELEVEN #32190(N-3810) , <br /> TANK INFORMA I1UN'. <br /> rMaterial: <br /> ID: Mtn. 5 Tank manifolded: NO Bottom to top fill in inches: 141.5 <br /> ct: MIDGRADE Vent manifolded: YES <br /> ns: 9,684 Bottom to grade in inches: 152.o <br /> Vapor recovery manifolded: YES Fill pipe length in inches: 51.5 <br /> s: 92.00 Overall protection: YES Fill pipe diameter in inches: 4.0 <br /> s: 356 Overspill protection: YES Stage I vapor recovery: DUAL <br /> ial: DW EISERG Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> .TANK TEST RESULTS Test Method:VacuTectLEAK DETECTOR TEST RESULTS Test method:LDT-5000 <br /> Start(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#t L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: VEEDERROOT <br /> Ingress Detected: Water Bubble Ullage Model: ELEcTRoNic <br /> Test time: S/N: H40002 <br /> Inclinometer reading: Open time in sec: <br /> VacuTect Test Type: NOT Holding psi: 22 <br /> TESTED Resiliency cc: NOT <br /> VacuTect Probe Entry Point: <br /> Pressure Set Point: Test leak rate ml/m: 189.0 TESTED Tank water level in inches: Metering psi: <br /> Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> LINE TEST RESULTS Test:type: TLD-i, <br /> LINE A B C D <br /> Material: DN FLEX <br /> Diameter(in): 1.5 <br /> Length(ft): 245.0 <br /> Test psi: 50 <br /> Bleedback cc: 16 <br /> Test time(min): 60 NOT NOT <br /> Start time: 11:17 NOT <br /> TESTED TESTED TESTED <br /> End time: 12:17 <br /> Final gph: 0.000 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 12/16/2009 08:21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.