My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/5/2018 8:19:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\COMPLIANCE INFO 2004-2007.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
226
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2240522 <br /> TEST DATE: 01/23/06 AUSTIN,TEXAS 78759(512)451-6334 <br /> CLIENT: 7-ELEVEN, INC. SITE: 7-ELEVEN #32190 <br /> TANK INFORMATION.-. <br /> Tank ID: Put, 6 Tank manifolded: No Bottom to top fill in inches: 140.0 <br /> Product: PREMIUM Vent manifolded: NO Bottom to grade in inches: 151.0 <br /> Capacity in gallons: 9,684 Vapor recovery manifolded: YES Fill pipe length in inches: 50.0 <br /> Diameter in inches: 90.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 356 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: BALANCE <br /> CP installed on: <br /> COMMENTS <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: VEEDERROOT <br /> Fluid volume in gallons: Model: ELECTRONIC <br /> Tank water level in inches: S/N: =reeaeme <br /> Test time: NOT Open time in sec: <br /> Number of thermisters: TESTED Holding psi: 21 NOT <br /> Specific gravity: Resiliency cc: TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Test time: <br /> Ullage volume: Material: ENvxxoN <br /> Ullage pressure: Diameter(in): 1.5 <br /> Results: Length (ft): 245.0 <br /> Test psi: so <br /> DATA FOR UTS-4T ONLY: Bleedback cc: 325 <br /> Time of test 1: Test time(min): 60 <br /> Temperature: NOT Start time: 09:52 NOT NOT NOT <br /> Flow rate (cfh): TESTED End time: 11:40 TESTED TESTED TESTED <br /> Time of test 2: Final gph: 0.003 <br /> Temperature: Result: PASS <br /> Flow rate (cfh): Pump type: PRESSURE <br /> Time of test 3: Pump make: FE PETRO <br /> Temperature: <br /> Flow rate(cfh): Impact Valves Operational: YES <br /> COMMENTS COMMENTS <br /> Printed 02/06/2006 08:19 SBOWERS <br />
The URL can be used to link to this page
Your browser does not support the video tag.