Laserfiche WebLink
IED PROGRAM CONSOLIDATED FORM TANK: TA0507939 <br /> PR#: PR0231074 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 FAC#: FA0002541 <br /> (two pages per tank) <br /> Page of <br /> TYPE OF ACTION <br /> ❑ INEW SITE PERMIT ❑ OAMENDED PERMIT ❑ SCHANGE OF INFORMATION ❑ 6TEMPORARY SITE CLOSURE <br /> (CBe`k only it=only) - ❑ 7 PERMANENTLY CLOSED ON SITE <br /> (Sidfyr m-for 1=1 ssse my) _ (Speciyv <br /> rson fohxttlo¢ oob) <br /> 3 RENEWAL PERMIT - ❑ STANK REMOVED s� <br /> BUSINESS NAME(samcas FAclurYNAMEm DEA-Dobgeusincss n,i FACILITY ID: PR#: <br /> 7 ELEVEN STORE#20632 B/2237 FA0002541 PR0231074 0. I <br /> LOCATION WITHIN SITE(Opuomn 4627 DA VINCI DR STOCKTON 431 <br /> PHONE D) <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 5 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ONO 434 <br /> TA0507939 TOTAL CONTAINMENT If-Y4s'.amryletenrupagefinexbmmpamnem s2 <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 '4V <br /> 4/29/1998 10,000 <br /> ADDITIONAL DESCRIPTION n orlocal me o*) 431 1"11G/ <br /> TANK USE 439 PETROLEUM TYPE D.TANK CONTENTS 40p h <br /> IM I.MOTOR VEHICLE FUEL ❑ la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (IfraarkN tonPlete Peunlem Tyye) ® Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(emn HanNous Motelab lmattorypage) 441 CAS#(firm Haoidm Materials lmmiory page) 442 <br /> ❑4.HAZARDOUS WASTE <br /> (Ircludc Uad DO) <br /> ❑ 95.UNKNOWN <br /> UL TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Cnakoneimnanly) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ® I.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 444 <br /> (Chxk one I=only) ❑2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/IN%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑99 OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (ChukomimnoNy) ❑ 2.STAINLESS STEEL ❑4.STEELCLADW/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100°/.METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL Dd 99.OTUUR l <br /> E] 5.CONCRETE Tit�1c JJ�j <br /> TANK INTERIOR LINING ❑ L RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Clock oom ilmsomy) ❑2 ALKYD LINING ❑4 PHENOLIC LINING ® 6 UNLINED ❑ 99.OTHER <br /> (Forlmlmconly) <br /> OTHER CORROSION ® 1 MANUFACTURING CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 441 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (ClotkmeaanoNy) ❑4 IMPRESSED CURRENT ❑ 99 OTHER <br /> E] 2SACRIFICIAL ANODE (Pmlml meanly) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(Imlcemy) 451 OVERFILL PROTECTION EQUIPMENT;YEAR INSTALLED 452 <br /> (Check att thin ppp <br /> apply) I SPILL CONTAINMENT 1,998.w I ALARM ❑ 3 FILL TUBE SHUT OFF VAL` <br /> � <br /> 2 DROP TUBE 5q`(8 2 BALL ❑ 4 EXEMPT <br /> 3 STRIKER PLATE ,q4B FLOAT <br /> IV.TANK LEAK DETECTION(A deception ofine mmMoringpro®am snnbesAntittd m tbelool agooy.) <br /> IF SINGLE WALL TANK(L7wek all not apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(Mm) (C am itrn city) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 1 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> 4/29/1998 0.00 gallons ❑yes ❑ No <br /> UPCF(12/99 revised) <br />