My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_1997-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
BILLING_1997-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:50:42 PM
Creation date
11/5/2018 8:20:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1997-2003
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\4943\PR0506488\BILLING 1997-2003.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e� <br /> *IED PROGRAM CONSOLIDATED FOR <br /> TANK <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check all that apply) rage _ of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE N 1.PRESSURE 0 2.SUCTION D 3.GRAVITY 458 0 1.PRESSURE [12 SUCTION 0 3.GRAVITY 459 <br /> CONSTRUCTION I 01.SINGLE WALL 0 3.LINED TRENCH 0 99.OTHER 460 0 1.SINGLE WALL 0 95.UNKNOWN 462 <br /> MANUFACTURER S 2.DOUBLE WALL [195.UNKNOWN [12.DOUBLE WALL 0 99.OTHER <br /> MANUFACTURER Environ 461 MANUFACTURER_ 463 <br /> 01.BARE STEEL 0 6.FRP COMPATIBLE w/70076 METHANOL [11.BARE STEEL 0 6.FRP COMPATIBLE wI100%MErHAN01. <br /> D 2.STAINLESS STEEL 0 7.GALVANIZED STEEL 0 UKNOWN 0 2. STAINLESS STEEL 0 7.GALVANIZED STEEL <br /> 03.PLASTIC COMPATIBLE W/CONTENTS 099. OTHER 03. PLASTIC COMPATIBLE W/CONTENTS 08.FLEXIBLE(HDPE) 099. OTHER <br /> N 4.FIBERGLASS S 8.FLEXIBLE(HDPE) 0 4. FIBERGLASS 0 9.CATHODIC PROTECTION <br /> 0 5.STEEL WICOATING [19.CATHODIC PROTECTION 464 1 D 5. STEEL W/COATING 0 95.UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall as submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 01. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE ANDVISUAL LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION«AUDIBLE AND VISUAL <br /> ALARMS. ALARMS. <br /> 02. MONTHLY 0.2 GPH TEST 02. MONTHLY 0.2 GPH TEST <br /> 03. ANNUAL INTEGRITY TEST(0.1GPH) 03. ANNUAL INTEGRITY TEST(O.IGPH) <br /> 04. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all Nazapply) <br /> 05. DAILY VISUAL MONITORING OF PUMPING SYSTEM TRIENNIAL PIPING INTEGRITY 05. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): 06. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> 07, SELFMONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW 07. SELF MONITORING <br /> 09. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> [18. DAILY VISUAL MONITORING <br /> 09. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Chad ane) (Chock are) <br /> Da. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS Da AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> St. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM 0 b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> Uc. NOAUTO PUMP SHUT OFF Dc NO AUTO PUMP SHUT OFF <br /> 511. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUTOFF OR 011, AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> 512. ANNUAL INTEGRITY TEST(0.1 GPH) 012. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUGTIONIGRAVITY SYSTEM <br /> 013. CONTINUOUS SUMP SENSOR*AUDIBLE AND VISUAL ALARMS 013. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> D14, CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND 014. CONTINUOUS SUMP SENSOR WITHOU AUTO PUMP SHUT OFF+AUDIBLE AND <br /> VISUALALARMS VISUALALARMS <br /> 015. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR 015. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> 016. ANNUAL INTEGRITY TEST(0.1 GPH) 016. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 0 17. DAILY VISUAL CHECK D 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER 01. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE 04,DAILY VISUAL CHECK <br /> CONTAINMENT <br /> DATEINSTALLED 46 02. CONTINUOUS DISPENSER PAN SENSOR,AUDIBLE AND VISUAL ALARMS 05.TRENCH LINER I MONITORING <br /> 2003 <br /> N3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+ 0 6.NONE 469 <br /> AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE' <br /> I certify that the in at i provided in is I end accurate to the best of my knowledge. <br /> SIGNATUR F OP DATE 470 <br /> NAME OF NER/OPRATOR(print) TITLE F 0wolIEWOPERATOR 472 <br /> Rand Martin Environmental Manager <br /> Permit Number(For local use only) 473 Pennil Approved(For local use only) Penn"Expiration Date(For local use only) <br /> 475 <br /> UPCF(1/99 revised) Formerly SV/RCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.