April 19, 1988 <br /> Page 3 <br /> B. Groundwater Well Construction <br /> 1. Casing Type, Diameter, Screen Interval, and Slot Size <br /> The monitoring well will be completed with the installation of factory <br /> threaded, 3-inch Schedule 40 PVC casing. The screen size will be factory <br /> slotted 0.020-inch. Based on a well completion depth of 40 feet and a <br /> static groundwater depth of 20 feet, screens will be placed from <br /> approximately 10 feet to 40 feet in depth, to allow for seasonal <br /> fluctuations in water levels. <br /> 2. Packing Depth and Size, and Seal Depth and Type <br /> Coarse aquarium or 12 x 20 sand will be used in the annular space from the <br /> depth of the boring to approximately 3 feet above the top of the screens. <br /> A one-foot thick bentonite seal followed by concrete to the ground surface <br /> will then be placed above the top of the sand pack. <br /> 3. Security <br /> A locking cap will be installed at the top of the well and shall be <br /> protected by a traffic rated concrete Christy box. <br /> 4. Development Procedure <br /> As part of the groundwater sampling procedure the well will be developed <br /> as described below under Groundwater Sampling. <br /> 5. Construction Diagram for each Well <br /> A construction diagram for each well will be submitted with the boring <br /> logs in the report which will be prepared following field activities. <br /> 6. Casing Elevation <br /> Surface elevations for each well will be surveyed to the nearest <br /> 0.01-foot, and survey data will be used to calculate groundwater <br /> elevations for the construction of groundwater contour maps, if <br /> appropriate. <br /> C. Groundwater Sampling <br /> 1. Water Level Measurement Procedure <br /> Prior to groundwater sampling, the water level will be measured to the <br /> nearest 0.01 foot. <br />