My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
2711
>
2300 - Underground Storage Tank Program
>
PR0231204
>
BILLING 1985-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2024 4:40:53 PM
Creation date
11/5/2018 9:05:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-2009
RECORD_ID
PR0231204
PE
2381
FACILITY_ID
FA0003793
FACILITY_NAME
LEARNER COMPANY, THE
STREET_NUMBER
2711
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
14503009
CURRENT_STATUS
02
SITE_LOCATION
2711 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAVY\2711\PR0231204\BILLING 1985-2009.PDF
QuestysFileName
BILLING 1985-2009
QuestysRecordDate
8/31/2017 7:30:16 PM
QuestysRecordID
3617633
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• STATEOFCAUFORMAON STATE WATER RESOURCES CONTROL BOARD UNDERGROUND STORAGE TANK PERMIT APPLICATION . FORM BCOMPLETE A SEPARATE FORM FOR EdH TANK SYSTEM. <br /> MARK ONLY r; I NEW PERMIT ❑ 1 RENEWAL PERMIT 5 CHANGE OF INFORMATION C T PERMANENTLY CLOSED ON SITE <br /> ONE ITEM 2 INTERIM PERMIT ❑ s AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> OBA OR FACILITY NAME WHERE TANK IS INSTALLED: , rI ✓-e- <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNERS TANK 1.0.a S. MANUFACTURED BY: ,r//io/ <br /> C. DATE INST ED(MOIDAWYEAR) C' 0. TANK CAPACITY IN GALLONS: ('_' 0 <br /> II.TANK Q&TENTS IFA-1ISMARKED.COMPLETEITEMC. <br /> A. 1 MOTOR VEHICLE FUEL ❑ A OIL a. C a REGULAR �OIESEJ'/ 6 AVIATION GAS <br /> UNLEADED `GI'SAi.O LJ <br /> ❑ 2 PETROLEUM ❑ a0 EMPTY / PRODUCT i lb PREMIUM '� A L T METHANOL <br /> ❑= u J S CHEMICAL PRODUCT ❑ 95 UNKNOWN 2 WASTE UNLEADED 5 JETF�EL <br /> 2 LEADED 99 OTHER (DESCRIBE IN ITEM O. BELOW <br /> 0. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.a: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,S.AND C.AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OF L I DOUBLE WALL ❑ S SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ A SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL I� 2 STAINLESS STEEL '`❑ 0 FIBERGLASS ❑ A STEELCLAD WIFIBERGLASS REINFORCED PLASTIC <br /> MATERIAL --71 5 CONCRETE ❑ 8 POLYVINYL CHLORIDE j❑ 7 ALUMINUM 8 100% METHANCL COMPATISLEWIFRP <br /> (Primary Tank) ❑ 9 SRONZE 10 GALVANIZED STEEL ❑ 95 UNKNOWN j;; 0 OTHER <br /> 1 RUBBER LINED ❑ 2 ALKYD LINING u 7 :?OXY LINING r A PHENOLIC LINING <br /> O INTERIOR <br /> LINING I—: 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN ❑ 98 OTHER <br /> ITIS--LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO_ <br /> D.CORROSION LJ I POLYETHYLENE WRAP ❑ 2 COATING ❑ 0 VINYL WRAP ❑ A FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION 5 CATHODIC PROTECTION (,❑ 91 NONE n 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV,PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 7 GRAVITY A U 99 OTHER <br /> S. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 0 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 7 POLYVINYL CHLORIDE(PVC)A U A FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U T STEEL W/CRATING A U 8 100% METHANOL COMPATIBLE WXRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHOOICP90TECTION A U 95 UNKNOWN A U 99 OTHER <br /> 0. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ MONBORNG ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ' 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 0 VADOZE MONITORING ❑ A AUTOMATIC TANK GAUGING L 5 GROUND WATER MONITORING <br /> I� 8 TANK TESTING ❑ ] INTERSTRIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> L ESTIMATED OATS T USED(_ AV/VR) 2.ESTIMATED QUANTITY OF ].WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONSI INERT MATERIAL? YES ❑ ND❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> ( INTED a SIGNATURE? DATE LL q <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY% JURISD�ICTIONI x FACILITY It TANK <br /> STATE I.D.# � j, 1—I— I -cc lial O I(/ <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE -!--�-�I PERMIT EXPIRATION DATE <br /> FORM 8 (?-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> PoROmt&R5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.