My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1989
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
2941
>
2300 - Underground Storage Tank Program
>
PR0503538
>
INSTALL_1989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 2:19:02 PM
Creation date
11/5/2018 9:09:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1989
RECORD_ID
PR0503538
PE
2381
FACILITY_ID
FA0009657
STREET_NUMBER
2941
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206-1149
APN
48906-1
CURRENT_STATUS
02
SITE_LOCATION
2941 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\N\NAVY\2941\PR0503538\INSTALL 1989.PDF
QuestysFileName
INSTALL 1989
QuestysRecordDate
10/3/2017 5:13:40 PM
QuestysRecordID
3659476
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEN UNDERGROUIRSTORAGE TANKS - PLAN ADDITION/C%ECTION SHEET <br /> The following checked and/or underlined items are to be addressed on plans: <br /> GENERAL <br /> et 1 . Provide the name and address of the facility. <br /> P. Provide the name. address, and phone numbers of the contractor(s) , facility <br /> owner(s), and operator(s). <br /> 3. Provide four complete sets of plans. (One to be retained by this office). <br /> Include specification sheets, equipment brochures, monitoring, and response <br /> plans. <br /> __�2L4. Provide plans to scale in nonerasable blueprint. <br /> CONSTRUCTION STANDARDS <br /> (1, 1 . Location(s) and number of tanks. <br /> _�C-2. Type of tank(s) to be installed. <br /> A. Steel clad with fiberglass reinforced plastic. <br /> 1 . 35,000 to 40,000 volt Holiday Test required before "setting" tank(s) <br /> l in ground. <br /> B. Fiberglass Modf_k S �u S uny Qovb(au7a¢{ <br /> 1 . Striker plate dimensions and materials. <br /> 2. Striker plates under all accessible openings. <br /> C. Nonclad steel <br /> 1 . Cathodic protection provided (including nuts, bolts, washers, etc. ). <br /> a. Approved by a corrosion engineer or NACE .technician. <br /> b. Document stating inspection method and frequency (Minimum semi- <br /> annual inspection required). <br /> D. Other types of tanks <br /> 1 . Construction specification standards for durability. <br /> 3. Tank Capacity (List specific gallonage) . &00 @3EQPoxe <br /> n� 4. Contents to be stored in each tank (Be specific). <br /> A. Verification of product compatability with the tank(s), piping, monitoring <br /> device(s) , epoxy or silicone glues , etc. <br /> 1 . List testing organization and approval . <br /> __L5)onitors , <br /> rovide manufacturers written installation instructions. (Include all piping, <br /> tan s , etc. <br /> Note - NFPA 30 Test required before covering tank and systems. NFPA 30 Test <br /> is require on BOTH the Primary and Secondary containment systems. <br /> Double walled tanks using pressure or vacuum testing to monitor annular <br /> space are exempt from testing secondary container. <br /> Note - NFPA 329 "Precision Test" required upon completion� of installations. <br /> nb e test result copy to be sent directly to this department from the <br /> testing company. <br />
The URL can be used to link to this page
Your browser does not support the video tag.