Laserfiche WebLink
I 161 D,3 <br /> NIFIED PROGRAM CONSOLIDATED FORT` TANK: TA0184807 <br /> PR#: PR0231848 <br /> UNDER%,ROUND STORAGE TANKS - TANK PAGE 1 FAC#: FA0002052 <br /> (two pages per(ank) <br /> Page 6 of 7 <br /> TYPE OF ACTION n 1 NEW SITE PERMIT n 4 AMFNnF.D PERMIT n S(HANGS OF INFORMATION []6 TEMPORARY SITE.CLOSURE <br /> (Check only item only) <br /> 7 PERMANENTLY CLOSED ON SITE <br /> 3 RENEWAL PERMIT <br /> (Specify reason-fm tical use poly) (Specify canon-for local use only)% 8 TANK REMOVED 430 <br /> 111 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: 1 <br /> ST SERVICES FA0002052 PR0231848 <br /> LOCATION WITHIN SITE(Optional) 3505 NAVY DR,STOCKTON 431 <br /> PHONE zC)q, (`/3. �6 <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 7 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes No 434 <br /> TAO 184807 v If"Yes",complete arc page for each compartment- <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAF YIN GALLONS 436 NUMBER OF COMPARTMENTS Jt7 <br /> AIA_ 1,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> 3/06/00 CHING PE FR 2315 TO 2360 PER MK.LBR <br /> 11.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE S40 <br /> ❑ 1.MOTOR VEHICLE FUEL ❑ la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (If marked complete petroleum Type) ❑ Ib.PREMIUM UNLEADED CX3.DIESEL ❑ 6.AVIATION FUEL <br /> ® 2.NON-FUEL PETROLEUM ❑ I c.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME <br /> ❑ (from,Hazrdow Materials Inven°ry page) 441 CASH(from Hazardous Materials Inventon Pa e <br /> ) 442 <br /> 4.HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN til-met rat <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ❑ I.BARE STEEL 1$ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100°A METHANOL <br /> REINFORCED PLASTIC(FRP) ❑99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/1000/6 METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ to.COATED STEEL ❑99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑3.EPDXY LINING ❑ 5.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ❑ 6 UNLINED ❑99.OTHER <br /> (for local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC 95 UNKNOWN 449 DATE INSTALLED a49 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑4 IMPRESSED CURRENT ❑ 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ❑ 1 SPILL CONTAINMENT B I ALARM ❑ 3 FILL TUBE SHUT OFF VAL' <br /> ❑ 2 DROP TUBE ❑ 2 BALL 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check one it-only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER [S] 2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BI ❑ 99 OTHER <br /> NK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED/DATE LAST USED(YR/MO/DAY) 455 JESTIMATED QUANTITY OF SUBSTANCE REMAINING ash TANK FILLED WITH INERT MATERIAL? 457 <br /> bZ ❑ Yes ❑ No <br /> UPCF(12/99 revised) 4 <br />