Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 Paae <br /> VI.PIPING CONSTRUCTION(Check as that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE 1 PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2. SUCTION 3. GRAVITY <br /> CONSTRUCTION/ 1. SINGLE WALL ❑ 3. LINEO TRENCH ❑99 OTHER 1. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER ❑ 2 DOUBLE WALL -/ ❑95. UNKNOWN ❑ 2. DOUBLE WALL 1-199. OTHER <br /> MANUFACTURER L/Yl`/I`e W/( / MANUFACTURER <br /> ❑ 1 BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL ❑ 1. BARE STEEL ❑ 8. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑95 UNKNOWN ❑ 3 PLASTIC COMPATIBLE WITH CONTENTS ❑ 8. FLEXIBLE(HOPE) ❑99. OTHER <br /> ❑ 4. FIBERGLASS ❑ 8. FLEXIBLE(HOPE) ❑99 OTHER. ❑ 4 FIBERGLASS ❑ B. CATHODIC PROTECTION <br /> 5 STEEL WI COATING ❑ 9. CATHODIC PROTECTION 5. STEEL W/COATING 1:195. UNKNOWN <br /> VII.PIPING LEAK DETECTION(Check all that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING - <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply). <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION-AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION;AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2. MONTHLY 0.2 GPH TEST <br /> ❑ 2. MONTHLY 0 2 GPM TEST <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GRH) <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPM) 4, DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS. CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> ❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0 1 GPH) ❑ 8. TRIENNIAL INTEGRITY TEST(0.1 GPM) <br /> �S.,A(FE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPINGy SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING)' <br /> IJU 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW. G VITY FLOW(Check all that apply)' <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0 1 GPH) 8. DAILY VISUAL MONITORING <br /> ❑ 9 BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10 CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check one) 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> ❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ D AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ <br /> C. NO AUTO PUMP SHUT OFF ❑ C. NO AUTO PUMP SHUT OFF <br /> ❑ 11 AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ <br /> RESTRICTION 11. AUTOMATIC LEAK DETECTOR <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM- <br /> 13 CONTINUOUS SUMP SENSOR-AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14 CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF AUDIBLE AND ❑ 14. CONTINUOUS SUMP CENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑ 18. ANNUAL INTEGRITY TEST(0,1 GPH) ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK ❑ IT DAILY VISUAL CHECK <br /> VIIL DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2. CONTINUOUS DISPENSER PAN SENSOR•AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER/MONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6. NONE <br /> IX.OWNERIOPERATOR SIGNATURE <br /> I certify that the information provided herein is We and 9#urate to the best of my knowledge. <br /> SIGNATURE OF OWNE PAT DATE <br /> NAM F WNER/q P T print TITLE OF OWNER/OPERATOR <br /> dr �rw3 - , 67y <br /> Permit Number(For local use only) Permit Approved(For local use only) Permit Expiration Date(For local use only) <br /> CUPAFORM(4199) Formerly SWRCB Form B <br />