My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2003-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
BILLING 2003-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:50:34 PM
Creation date
11/5/2018 9:19:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2003-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAVY\3515\PR0231210\BILLING 2003-2015.PDF
QuestysFileName
BILLING 2003-2015
QuestysRecordDate
8/4/2017 11:46:01 PM
QuestysRecordID
3555730
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> 304 E.Weber Ave-,Third Floor*Stodcron,CA 95202-2708 a Phone(209)468-3420 <br /> Donna Heran,REH.S.,Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program Permit Permit <br /> Record ED Number Program Code and Description. Valid <br /> PRO514502 PT0010705 2227-HAZARDOUS WASTE GENERATOR FACILITY 1/1/2007 To 1213112007 <br /> Hazardous Waste Generator Program: <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20,Chap.6.5,Art.2-13, <br /> Sec_25100 at seq,and Title 22 I is Code of Regulations,Chap,20;___,___ <br /> PR0231210 2300-U DERGROUND STORAGE TANK FACILITY 1/1/2007 To 12/31/2007 <br /> Under round Storage T k Pro ram: <br /> California Health and afety Code_ iv.20,Chap.6.7 and Title 23,California Code of Regulations,Chap. 16. _ _ <br /> --------------------- ---------- --- -------- -------- ------ - ------ <br /> P/E Tank I Tank R rd ID Permit# Capacity Contents Permit Status - System Type Leak Detection <br /> 2362 5 390002312100121005 PT0004551 6,000 OTHER Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> BOE IN 44-000074' <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain theoperatingpemdt,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions <br /> established by San Joaquin County. <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other thantheowner or operator of the tank,the Permittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) Written Monitoring Proceduresand an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The.approved <br /> monitoring,response,and plot plans shall be maintained onsite with the pemtil. <br /> 5) The Pemdttee shall comply with the monitoringpmcedures referenced in this permit. <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified.by the equipment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized release,the Perrnitee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan. <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the data the monitoring was <br /> performed. <br /> 9) The EHD shall be notified of my change in ownership or operation of the UST system within 30 days of such change. <br /> 10) -Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 11) Construction,repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment. <br /> 12) The Permittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of the date of the issuance ofthis permit. <br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. <br /> 14) A"Conditional'Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated.' <br /> PERMITS TO OPERATE are NOT TRANSFERABLE <br /> and may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: SHELL OIL PRODUCTS US <br /> Tank Owner: SHELL OIL CO STOCKTON PLANT <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility: SHELL OIL Facility ID FA0003747 <br /> 3515 NAVY DR Account ID AR0003326 <br /> STOCKTON CA 95203 Issued 2/13/2007 <br /> Billing Address: <br /> SHELL OIL <br /> 3515 NAVY DR <br /> STOCKTON CA 95203 <br /> 7023.rpt <br />
The URL can be used to link to this page
Your browser does not support the video tag.