My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NEWTON
>
4051
>
2300 - Underground Storage Tank Program
>
PR0231868
>
REMOVAL_2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2024 4:53:40 PM
Creation date
11/5/2018 9:50:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2003
RECORD_ID
PR0231868
PE
2361
FACILITY_ID
FA0004045
FACILITY_NAME
AT&T California - UER47
STREET_NUMBER
4051
STREET_NAME
NEWTON
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
4051 Newton Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NEWTON\4051\PR0231868\REMOVAL 2003 .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 2 <br /> Calibration and Maintenance of Field Sampling Equipment <br /> Monitor Type Calibration Method Calibration Frequency Maintenance Schedule <br /> Combustible gas CGI sensor calibrated against CGI span calibrated once per Instrument cleaned as needed <br /> indicator(CGI)/oxygen known concentration of hexane month. CGI zero checked and no less than annually. <br /> meter14 gas meter(02, (demonstration bottle). Zero setting daily. Oxygen sensor changed <br /> LEL,hydrogen sulfide, checked in non-contaminated air. annually and changes if <br /> and carbon monoxide) necessary. <br /> Oxygen sensor calibrated <br /> Oxygen sensor calibrated daily to daily. <br /> 20.9 percent fresh, <br /> non-contaminated air. <br /> Photoionization detector PID zeroed in clean air. Span PID zeroed and span checked Annual cleaning by qualified <br /> (PID) calibrated using known daily at start of work day. technician. Annual calibration <br /> concentration of isobutylene of electronics by qualified <br /> (demonstration bottle). technician. Clean lamp if <br /> sensitivity drops or if used in <br /> very dusty environment. <br /> Draeger tube sampling Check air tightness of pump,time Check daily prior to start of Maintenance required <br /> system for one minute,chain should remain workday. whenever pump fails to pass <br /> slack. If chain taut,then leak test. Replace seals <br /> maintenance required. andlor lubricate per instruction <br /> manual. <br /> Air sampling pump Verify airflow using primary standard Verify airflow prior to and after Minimum of annual cleaning. <br /> (bubble meter)or precalibrated use with sampling head in Clean whenever pump unable <br /> rotameter. place. Spot check flow rate to hold flow rate. <br /> throughout sampling period. Maintenance required if pump <br /> will not hold charge or flow <br /> rate is erratic. <br /> CNCD:dH..4RE'!.C/SP.P'-0OB3.doo 1 of I <br />
The URL can be used to link to this page
Your browser does not support the video tag.