My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NEWTON
>
4051
>
2300 - Underground Storage Tank Program
>
PR0231868
>
INSTALL_1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2024 4:53:10 PM
Creation date
11/5/2018 9:54:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995
RECORD_ID
PR0231868
PE
2361
FACILITY_ID
FA0004045
FACILITY_NAME
AT&T California - UER47
STREET_NUMBER
4051
STREET_NAME
NEWTON
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
4051 Newton Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NEWTON\4051\PR0231868\INSTALL 1995.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Date: 1/16/95 <br /> M- ORIMI STINE <br /> Tank Monitoring Equipment - Recertification <br /> Facility Name: Pacific Bell, 4051 Newton Road, Stockton Facility ID: SKTNCAI6 <br /> Using the capabilities of the USTAS system, a program was written to run once each year according to <br /> Veeder-Root's specifications and print the results for each tank location. <br /> There are three diagnostic test each for the main and option boards: <br /> • The probe test is a capacitance test for each probe segment. <br /> • The leak test report shown is actually the results of the last test ran in regular daily testing. <br /> • The annual test shows an "all tests passed" condition. This is to be expected as any time there is a <br /> failure in these areas we would be notified during our daily polling. <br /> Copies of remote diagnostic reports are available by contacting Environmental Management on 510-867-5025. <br /> In addition,physical calibration and physical inspection to recertify the monitoring equipment is accomplished <br /> through a qualified vendor. The Real.Estate Engineer will make the arrangements to have the recertification <br /> done. <br /> } <br /> Yp{ <br /> pg . 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.