Laserfiche WebLink
FIED PROGRAM CONSOLIDATED FORM I ( TANK: TA0144602 <br /> I PR#: PR0231446 <br /> UNDERGROUND STORAGE TANKS - TAN FAC#: FA0000853 <br /> ( (two pages <br /> Pag <br /> TYPEOFACTION ❑ INEW SITE PERMIT ❑ 4AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6TEMPORARYSITEC OSURfCI <br /> (Cberk oNyb�OnH) `S: ' "s ❑ 7PERMANENTLV EDO I_.u1e <br /> ISpadfy.amn-fmkcalwewy) (Spm „6ck 1nseonly3 <br /> ❑ 3 RENEWAL PERMIT STANK REMOVED o <br /> - El <br /> BUSINESS NAME(Same as FACILITY NAME m DBA-Doing Rwinns AS) FA('ILI II ID: PRI;: 1 <br /> DOCTORS HOSPITAL OF MANTECA FA0000853 PR0231446 <br /> LOCATION WITHIN SITE(Oprimup 1205 E NORTH ST,MANTECA 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plat plan with the location of the UST system including buildings and lasMmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 2 432 TANK MAWAC_TURRER 4p I COMPARTMENTALIZED TANK E:1 Yes El No 434 <br /> TA0144602 10VJfrk cor NI If Na'.compine onepa8c fw®ch rn�annunt <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACEIY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 550 <br /> ADDITIONAL DESCRIPTION(Fo.1.1 meomy) 439 <br /> H.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE dao <br /> M I.MOTOR VEHICLE FUEL ❑ is.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (Ifmukadc ieef`w] nTypc) ❑ lb.PREMIUM UNLEADED ®3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM ❑ Ic MIDGRADE UNLEADED ❑ 4.GASOHOL [:199.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(r Haa.doua mucoab lmmwypage) 441 CAS#(t HoaNas page) 442 <br /> ❑4.HAZARDOUS WASTE <br /> (Iveludo Used Oil) <br /> ❑95.UNKNOWN <br /> HL TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (CMck on<ken 0*) EXTERIOR MEMBRANE LINER [195.UNKNOWN <br /> ®2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Clickn item only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99 OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL K3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (CM1ak one imm only) ❑ 2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FTBERGLASS ❑ s.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Omckoncita Wy) ❑ 2ALKYD LINING ❑4PHENOLIC LINING El6UNLINED ❑ 99.OTHER (Fmtmlmcmly) <br /> OTHERCORROSION ❑ I MANUFACTURING CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED m9 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑4IMPRESSED CURRENT E:199OTHER <br /> (Ch .imnmJ <br /> y) ❑ 2SACRIFICIAL ANODE (Far lanl me ovH) <br /> SPILLANDOVERFILL YEAR INSTALLE450 TYPE(I Iwccoly) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Camkall Nat apply) ❑ 1 SPILL CONTAINMENT ❑ 1 ALARM ❑ 3 FILL TUBE SHUT OFF VAL` <br /> ❑ 2 DROP TUBE ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> N.TANK LEAK DETECTION(Adescription ofde=nimrizgpm9runsull beaubmiaMm 9K bal 29 ) <br /> IF SINGLE WALL TANK(CMkall lheappH) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (CMck arc hen only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ STANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DA LAST ED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 459 <br /> }� ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />