EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NORTH RIPON
>
23101
>
2300 - Underground Storage Tank Program
>
PR0503801
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2021 10:06:39 PM
Creation date
11/5/2018 10:03:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0503801
PE
2332
FACILITY_ID
FA0005980
FACILITY_NAME
MORRISON HOMES
STREET_NUMBER
23101
STREET_NAME
NORTH RIPON
STREET_TYPE
RD
City
RIPON
Zip
95366
CURRENT_STATUS
02
SITE_LOCATION
23101 NORTH RIPON RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NORTH RIPON\23101\PR0503801\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/3/2017 7:47:54 PM
QuestysRecordID
3716990
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATEOFCAUPORMA <br /> STATE WATER RESOURCES CONTROL BOARD i <br /> - UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B <br /> COMPLETE A SEPARATE FORM FOR EA NK SYSTEM <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT EPr5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 8 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED Q <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: �f /��S ' 3/O /PW . <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.a / B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) r<n1-n vw i. D. TANK CAPACITY IN GALLONS: <br /> II.TANK C EMS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> 1a REGU 3 DIESEL <br /> A. i MOTOR VEHICLE FUEL ❑ d OIL B. C. ❑ UNL ED ❑ e AVIATION GAS <br /> 4 GASAHOL <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ 1 UNLEADED 5 JET FUEL ❑ 7 METHANOL <br /> ❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE Ln 2 LEADED g 99 OTHER (DESCRIBE IN ITEM O. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.II: <br /> III. TANK CONSTRUCTIO MARK ONE ITEM ONLY IN BOXES A,B,AND C.AND ALL THAT APPLIES IN BOX <br /> A. TYPE OF ❑ U8LE ALL F73 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 S LE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> S. TANK1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS E::] 4 STEELCLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVAN D STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED _ <br /> 2 AL4D LINING E:] 3 EPDXY LINING E:] d PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING 6 UNLINED ❑ 96 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 ATING ❑ 3 VINYL WRAP ❑ d FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A WAL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U UNKNOW p U 99 OTHER <br /> C. MATERIAL AND p 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U- A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ e IMMONRORINOL ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VA -ONITORING❑ d AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> ❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATEC QUANTITY OF 3.WAS TANK FILLED WITH YES NO <br /> "I 'EU SUBSTANCE REMAINING GALLONS INERTMATERIAL? ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> (PRINTED a SIGNATURE( <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.# a] I 1 1 y p <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> FORM B (9.90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORMA,UNLESS A CURRENT FORMA HAS BEEN FILED. <br /> s FOR110,I 6 C1 <br /> /V <br />