My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
22335
>
2300 - Underground Storage Tank Program
>
PR0501933
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:20:09 AM
Creation date
11/5/2018 10:30:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0501933
PE
2333
FACILITY_ID
FA0005275
FACILITY_NAME
MICHAEL HAT FARMING CO
STREET_NUMBER
22335
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
AVE
City
RIPON
Zip
95366
APN
22814005
CURRENT_STATUS
02
SITE_LOCATION
22335 S OLIVE AVE
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\O\OLIVE\22335\PR0501933\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
3/5/2018 7:52:09 PM
QuestysRecordID
3818170
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• " co ^ <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD ` <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED p/ <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 3 C <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.• B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MOIDAYNEAR) L oL_ D. TANK CAPACITY IN GALLONS: <br /> ILTANKCONTENTS IFA-11SMARKED,COMPLETE ITEM C. <br /> q. ❑ 1 MOTOR VEHICLE FUELO 6 OIL S. C. ❑ 1aUNLEADED 8 FIEGULAFI 3 DIESEL ❑ 6 AVIATION GAS <br /> 2 PETROLEUM 80 EMPTY 1 PROOUCT ❑ ib PREMIUM 11I��� 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ,WNLEADED 9B4OTHERL(DESCRIBE IN ITEM D. BELO'N) <br /> 2 LEADED u <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.a <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLVI BOXES A S.AND C,AND ALL THAT APPLIES IN BOX <br /> 1 DOUBLE WALL 3 SINGLE WALL WITH EXTERIOR LINER <br /> A. TYPE OF ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> B. TANK EEf1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED [:] 2 ALKYD LINING ❑ 3 OXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR <br /> LINING ❑ 5 GLASS LINING ❑ 6 UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL 7 YES_ NO— <br /> D. POLYETHYLENE WRAP 2 COATING y1N1' <br /> D.CORROSION ❑ ❑ 3 L WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION 5 CATHODIC PROTECTION ❑ 91 NONE ,L�N UNKNOWN 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUN OR U IF NDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A - A U 3 GRAVITY p U W OTHER <br /> B. CONSTRUCTION1 SINGLFW A U BL WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U I BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETEC'nR ❑ 2 LINE TIGHTNESS TESTING ❑ SP k gg OTHER <br /> _. MONITORING ❑ <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VAP NITORING❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING E] 7 INTERSTITIAL MONITORING 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERTMATERIAL7 YES ❑ NO ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED 8 61GNANREI DATE <br /> LOCAL AGENCY USE ONLY THE STATE 1.0.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE I.D.# <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE - --Lz-�LPERMIT EXPIRATION—DATE <br /> FORM B (9.90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FOR00516R8 <br />