Laserfiche WebLink
I <br /> MAINTENANCE HISTORY <br /> DISABLED <br /> LATHROP GAS N FOOCr TANK <br /> 14800 W. FRONTAGE RD DISABLEDRT SECURITY <br /> MANTECA CA, 95336 <br /> 209-239-2717 I <br /> I( CUSTOM ALARMS <br /> DEC 2, 2009 9:54 AM DISABLED <br /> IN—TANK SETUP <br /> MASS/DENSITY — _ _ — — — — — — — — — <br /> SYSTEM STATUS REPORT DISABLED <br /> — — — — — — — — — — — — T I :UNLEADED <br /> ALL FUNCTIONS NORMAL PRODUCT CODE 1 <br /> THERMAL COEFF : .000700 <br /> TANK DIAMETER 91 .70 <br /> TANK PROFILE 4 PTS <br /> FULL VOL : 9696 <br /> 68.8 INCH VOL : 7865 <br /> 45.8 INCH VOL 4856 <br /> 22.9 INCH VOL 1860 <br /> SYSTEM SETUP FLOAT SIZE: 4.0 IN. <br /> — — — — — — — — — — — — COMMUNICATIONS SETUP <br /> DEC 2, 2009 9:54 AM — — — — — — — — — — — — WATER WARNING 2.0 <br /> HIGH WATER LIMIT: 2.5 <br /> PORT SETTINGS: MAX OR LABEL VOL: 9696 <br /> SYSTEM UNITS OVERFILL LIMIT 95% <br /> U, . COMM BOARD : 1 (EDIM ) 9211 <br /> SYSTEM LANGUAGE RS-232 SECURITY HIGH PRODUCT 90% <br /> ENGLISH CODE : DISABLED 8726 <br /> SYSTEM DATE/TIME FORMAT DELIVERY LIMIT 10% <br /> ` MON DD YVYY HH:MM:SS xM COMM BOARD 2 (RS-232) 969 <br /> BAUD RATE 9600 <br /> LATHROP GAS N FOOD PARITY : ODD LOW PRODUCT 562 <br /> 14800 W. FRONTAGE RD STOP BIT 1 STOP LEAK ALARM LIMIT: 99 h <br /> MANTECA CA, 95336 DATA LENGTH: 7 DATA SUDDEN LOSS LIMIT: 99 <br /> 209-2.39-2717 RS-232 SECURITY TANK TILT 0.001 <br /> CODE : DISABLED PROBE OFFSET 0.00 <br /> SHIFT TIME 1 11 :59 PM <br /> SHIFT TIME 2 5:00 AM <br /> SHIFT TIME 3 DISABLED AUTO TRANSMIT SETTINGS: SIPHON MANIFOLDED TANKS <br /> SHIFT TIME 4 DISABLED TO: NONE <br /> AUTO LEAK ALARM LIMIT LINE MANIFOLDED TANKS <br /> TANK PER TST NEEDED WRN DISABLED TO: NONE <br /> DISABLED AUTO HIGH WATER LIMIT <br /> TANK ANN TST NEEDED WRN DISABLED <br /> DISABLED AUTO OVERFILL LIMIT LEAK MIN PERIODIC: Ord <br /> DISABLED 0 <br /> LINE RE--ENABLE METHOD AUTO LOW PRODUCT <br /> PASS LINE TEST DISABLED LEAK MIN ANNUAL : 0% <br /> AUTO THEFT LIMIT 0 <br /> LINE PER TST NEEDED WRN DISABLED <br /> DISABLED AUTO DELIVERY START <br /> LINE ANN TST NEEDED WRN DISABLED PERIODIC TEST TYPE <br /> DISABLED AUTO DELIVERY END STANDARD <br /> DISABLED <br /> PRINT TC VOLUMES AUTO EXTERNAL INPUT ON ANNUAL TEST FAIL <br /> ENABLED DISABLED ALARM DISABLED <br /> AUTO EXTERNAL INPUT OFF <br /> TEMP COMPENSATION DISABLED PERIODIC TEST FAIL <br /> VALUE (DEC F ) : 60.0 AUTO SENSOR FUEL ALARM ALARM DISABLED <br /> STICK HEIGHT OFFSET DISABLED <br /> DISABLED AUTO SENSOR WATER ALARM GROSS TEST FAIL <br /> ULLAGE: 90% DISABLED ALARM DISABLED <br /> AUTO SENSOR OUT ALARM <br /> H—PROTOCOL DATA FORMAT DISABLED ANN TEST AVERAGING: OFF <br /> HEIGHT PER TEST AVERAGING: OFF <br /> DAYLIGHT SAVING TIME <br /> DISABLED TANK TEST NOTIFY: OFF <br /> RE—DIRECT LOCAL PRINTOUT <br /> DISABLED TNK TST SIPHON BREAKOFF <br /> EURO PROTOCOL PREFIX; DELIVERY DELAY 3 MIN <br /> S PUMP THRESHOLD 10.00% <br /> RS-232 ENI) OF MESSAGE <br /> DISABLED <br />