D. Results of Testing/Servicing <br /> Software Version Installed: 327.04 <br /> Com late Ilowlinq checklist: <br /> ® Yes ❑ No' Is the audible alarm operational? <br /> Yes ❑ No' Is the visual alarm operational? <br /> Yes ❑ No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ® Yes ❑ No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br /> operation? <br /> ❑ Yes ❑ No' If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.,modem)operational? <br /> ® N/A <br /> ® Yes <br /> El For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, <br /> ted? if yes:which sensors initiate positive shut-down? (Check all that apply) SumplTrench <br /> Cl NIA fails to operate, or is electrically disconnected? <br /> Sensors; 0 Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes; ❑No. <br /> El Yes Cl No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i,e., no mechanical overfill prevention valve is <br /> )� NIA installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly? If so,at what percent of tank capacity <br /> does the alarm trigger? 0% <br /> ❑ Yes ® No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced and list the manufacturer name <br /> and model for all replacement parts in Section E.below. <br /> ❑Yes' ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> El Product; El Water. If yes,describe causes in Section E,below. <br /> ® Yes ❑ No Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ® Yes ❑ No' Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> INSPECTOR ARIS ON SITE . . ARIS HAS ALL PRINT OUTS. 91 LD FAILED . 87 BUCKET FAILED . <br /> INSPECTOR ARIS FOUND A DIP STICK INSIDE OF DROP TUBE .ALSO 91 STP SENSOR WAS ON <br /> WRONG SIDE OF SUMP. CORECTED ON SITE . ELITE a WILL FIX ALL REPAIRS AND RETEST LD <br /> E. Comments: ASAP <br /> Monitoring System Certification Page 2 of 4 2/21/07 <br />