Laserfiche WebLink
• San Joaquin County <br /> o p a Environmental Health Department DrRecroR <br /> Donna Heran, REHS <br /> 600 East Main Street <br /> -t PROGRAM COORDINATORS <br /> 0: Stockton, California 95202-3029 Robert McClellon,REHS <br /> Jeff Carruesco, REHS,RDI <br /> ' ��•' o4ey, <br /> Kasey F , REHS <br /> c <br /> ,16�.,.CjiP website: www.sjgov.org/ehd Linda oleyte, REHS <br /> _11 Phone: (209) 468-3424 <br /> Fax: (209) 464-0138 <br /> Carrie Miller <br /> Elite IV Contractors <br /> 2535 Wigwam Dr. <br /> Stockton, CA 95205 <br /> Re: Lathrop Gas & Food 14800 S. Hwy 99 Manteca, CA 95336 SR0064078 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the permit application for installing a new VMI 99-LD2000 mechanical line leak detector for the <br /> 91 product and installing a new OPW drain valve kit for the 87 fill spill container on the <br /> underground storage tank (UST) system at the above noted address. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Aris Cacapit at (209) 468-3453 to arrange the following inspection appointments <br /> (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Leak detector test: Leak detector must be tested to confirm that the device can <br /> detect a leak of 3 gallons per hour at 10 psi. <br /> b. Overfill prevention verification: Visual inspection of the 87 drop tube to verify that the <br /> stick has been removed so that it can no longer prevent the mechanical flapper from <br /> functioning properly. <br /> c. Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic <br /> test(or equivalent). Proper drainage must also be verified. <br /> Please be aware that the facility cannot receive fuel in the 87 tank prior to the EHD <br /> inspection and approval. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid, current contractor's licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Tester's license issued to the individual by the State Water Board, and <br /> b. A valid, current California UST Service Technician certificate issued by the <br /> International Code Council (ICC), and <br />