Laserfiche WebLink
0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street„ Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.smgov.or-q/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> Lathrop Gas and Food Mart December 20, 2010 <br /> Facility address: UST#1 4 5 6 <br /> 14800 Frontage, Hwy 99, Lathrop Product 77 DSL 91 <br /> Facility contact Title: Phone: <br /> Jesse Owner — Z 71 '7 <br /> (Monitoring panel: IMP'e6sunzedESrrcticmnO'_r_' * <br /> Piping system: t7verfill preve�etion: Violations: <br /> Veeder-Root TLS-350 Mechanical❑Audiblehrisual ❑M1-RDeiect❑M2-RPrev❑M3-loth <br /> Inspection type: Designated operator. ICC exp.date: <br /> ®Routine [K Monitoring Certifiration ❑Installation ❑oher Mathew Hasley 7' 2 172— <br /> On <br /> 'ZOn site Service Technician's name; ICC exp.date: Ntanufacturer's training: <br /> David Winkler 9,1,;4d -- 31/0'/2_ <br /> Code Section VIOLATIONS R <br /> HSC=CA Health&Safe Code;CCR=CA Code of R ulations;V=Violation;RV=R t Violation V V <br /> 1 HSC 25284 Na permR to operate <br /> Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EMD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or approved by the EHD X <br /> 6 CCR 2712(i) Monitoring plan,response plan,and/or operating rmit and all conditions not onsite <br /> Maintenance&monitoring fecords not maintained 3 years,cathodic protection records for 6'/ (iM1) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings,and upgrades for the life of the tank_ Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field;(5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed Irn) <br /> 9 HSC 25292.1 UST system is not operated.to prevent unauthorized release,including ills and overfills <br /> 10 CCR 2632(c)(2) Monitorinq s stem is not present in the interstitials ace of a double walled UST (M1) <br /> 11 CCR 2630(d) UST moiiFitoring equipment is not installed or maintained to detect a leak at the earliest rtun (rt1) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (rat) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (airs) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a3-gallon per hour leak at 10 psi (1111) <br /> 18 CCR 2635(b)(1) Spall container failed to contain a minimum capacity of five gallons,or failed to provide a means (u12) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (1112) <br /> 20 CCR 2636(a) Failed to have seconds containment for pipi includes conventional suction piping) (1112) <br /> 21 HSC 25291(e) Water in 2'containment not removed,anal ed&prorlydisposed of <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight (111) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated opgrator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current IC ST System Operator certification <br /> EHD inspector Received by; Title: <br /> EHD 23-02-002 REV 08113110 Page 1 UST INSPECTION REPORT <br />