My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Q
>
QUAIL LAKES
>
4661
>
2300 - Underground Storage Tank Program
>
PR0528872
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 10:44:10 AM
Creation date
11/6/2018 9:06:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528872
PE
2332
FACILITY_ID
FA0018642
FACILITY_NAME
QUAIL LAKES CAR WASH
STREET_NUMBER
4661
STREET_NAME
QUAIL LAKES
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11220025
CURRENT_STATUS
02
SITE_LOCATION
4661 QUAIL LAKES DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\Q\QUAIL LAKES\4661\PR0528872\COMPLIANCE INFO 2017 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
11/27/2017 5:56:26 PM
QuestysRecordID
3735675
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN .JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.s'gov.org/ehd <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection <br /> Date:: <br /> i � La.iCus �r I.•-�49 L-- hog.;. ��l Z�} aS� <br /> Facility address: UST# <br /> V 'Product <br /> Facility Contact: Title: Phone: <br /> Monitoring Panel: Piping system: Overfill prevention: <br /> rE�.L X'Pressurized ❑Suction ❑Gravity ❑Mechanical ❑Audible/visual <br /> Inspection type: =,..q o F (..abs—SA-P gmmx"f— us T�- Violations: <br /> ,AKRoutine ❑Monitoring Certification ❑ Installation ❑Other: ❑M1-RDetect ❑M2-RPrev ❑M-3 Both <br /> VIOLATION(S) HSC=California Health &Safety Code; CCR=California Code of Regulations V R <br /> # Code Section V <br /> V=Violation; RV=Re eat Violation <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b & c Current Unified Program Consolidated Forms on file with EHD (Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 b Monitoring Program (Monitoring & Response Plan is current and approved by the local agency. <br /> 6 CCR 2712 i Monitoring Ian is onsite. <br /> 7 CCR 2712 b Maintenance & monitoring records M1 <br /> 8 CCR 2643 d Daily monitoring of suction piping (pre-January, 1, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632 (c)(2) UST monitoring system is present M1) <br /> 11 CCR 2630 d UST system monitoring equipment is properly located to detect a leak M1 <br /> 12 HSC 25291 b UST system monitoring equipment isoperational M1) <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping& UDC is present M1 <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detector(s) are installed M1 <br /> 18 CCR 2635 (b)(1) Spill container (M2) <br /> 19 CCR 2635 (b)(2) Overfill prevention system M2 <br /> 20 CCR 2636 (a) Conventional suction piping shall have continuous monitoring& 20 containment <br /> 21 HSC 25291 (e) Water in 21 containment analyzed & properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases M1 <br /> 23 CCR 2715 Designated Operator: a Statement from UST owner; (c-e) Monthly inspection; Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638 a Annual line leak detector test M1 <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test M1 <br /> 28 CCR 2661 Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 e Biennial tightness test of gravity pipingre-Janus 1, 1984 <br /> 30 CCR 2643 d Triennial line test for conventional suction piping ( re-Janus 1, 1984) (M1) <br /> 31 HSC 25292.5 Double walls stem located within 1000' of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> r34 HSC 25298 b Permit to temporarily close UST system <br /> 35 HSC 25298 c Permit to close UST system <br /> 36 HSC 25299 Disabling leak detection devices <br /> a 9 2 <br /> 37 HSC 25298 a Illegal abandonment of UST system <br /> 38 Other: 4 Z !P� _�r 142---v <br /> EHD INSPECTOR: PHONE: UIC <br /> Septic system: <br /> Serves>20 people/day <br /> RECEIVE Y: TITLE: Receives other than sanitary waste <br /> 6vl� Other disposal methods: <br /> . D Dry wells/French Drains <br /> EHD 23-02-002 REV 8/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.