My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
31
>
2300 - Underground Storage Tank Program
>
PR0502451
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 3:47:56 PM
Creation date
11/6/2018 9:13:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0502451
PE
2381
FACILITY_ID
FA0005451
FACILITY_NAME
LODI USD-MAINT & OPERATIONS*
STREET_NUMBER
31
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
03511012
CURRENT_STATUS
02
SITE_LOCATION
31 N PACIFIC AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\31\PR0502451\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
6/2/2016 3:48:51 PM
QuestysRecordID
3100363
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIf WATER RESOURCES CONTRO! 'OARD <br /> FORM 'B': UNDEf,ROUND STORAGE TANK PROftAM ' <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. " Z <br /> S O <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑A K REMOVED 09 N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 51 1 PQC,I 1 CcU FARM TANK-YES❑ NO .OJ. <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY 00 <br /> A. OWNERS TANK]DO ' uo—%i B. MANUFACTURED BY: <br /> C. YEAR INSTALLED I "'I D. TANK CAPACITY IN GALLONS: <br /> II. TANK CO ENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OILODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,a D <br /> A.TYPE OF ❑ 1 DOUBLE 0 ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> 1 STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑ 8100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ u— K.� <br /> C. INTERIOR 1 RUBBER LINED ❑ 2 ALKYD LINING ❑3 EPDXY LINING F—] 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑ 6 UNLINED UNKNOWN <br /> / <br /> F-1ISLINING MATERIAL COMPATIBLE WITH Ioft MEMANOL? E:]YES ❑ NO PER <br /> D. CORROSION ❑ 1 POLYETHLENEWRAP ❑2TAR OR ASPHALT ❑ 3VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE E: 1 N ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1,AUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINEDTRENCH A U 91 NONE A U 9 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL 95 NKNOWN A U 99 OTHER <br /> V. LEAK DETECTION YSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1VISUALCHECK Ued2 INVENTORY RECONCILIATION P S 3VADOSEWELLS P S 4 ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> P S 6 PRECISION TESTIN P 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> IF <br /> CURRENT LOCAL AGENCY FACILITY ID N APPROVEDRYINAME PHONE ITH AREA CODE <br /> �YJ 1 "3 I <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT N BY: <br /> FORMB(6-29-88) THIS FORM MUST BE ACCOMPANIE BYAFACILITY/SITE APPLICATION, FORM 'A',UNLESS nn#RRENT FORM'A' HASBEENFILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.