Laserfiche WebLink
IFIED PROGRAM CONSOLIDATED FO TANK <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check all that apply) Page 5 of 5 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ®1.PRESSURE ❑2.SUCTION ❑3.GRAVITY 458 ❑1.PRESSURE [12. SUCTION [13.GRAVITY 459 <br /> ❑95.UNKNOWN 962 <br /> CONSTRUCTION/ ❑1.SINGLE WALL ❑3.LINED TRENCH ❑Nu.OTHER 460 ❑1.SINGLE WALL <br /> MANUFACTURER ®2.DOUBLE WALL [195.UNKNOWN ❑2.DOUBLE WALL [199,OTHER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> ❑1.BARE STEEL 0 6.FRP COMPATIBLE W00% METHANOL ❑1.BARE STEEL ❑6.FRP COMPATIBLE W1100%MEMANOL <br /> ❑2.STAINLESS STEEL [17.GALVANIZED STEEL ❑UKNOWN ❑2. STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> [13.PLASTIC COMPATIBLE W/CONTENTS ❑99. OTHER [13. PLASTIC COMPATIBLE WI CONTENTS ❑B.FLEXIBLE(HDPE) [199. OTHER <br /> [:14.FIBERGLASS ❑B.FLEXIBLE(HDPE) ❑4. FIBERGLASS [19.CATHODIC PROTECTION <br /> ❑5 STEEL WICOATING [19.CATHODIC PROTECTION 464 1 ❑5 STEEL WICOATING ❑95.UNKNOWN <br /> 465 <br /> VII.:PIPING LEAK DETECT ION(Check all that apply)(A description of the monitoring program shelf be submitted to the local i ency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR 01. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL LAEAKK,ASS STEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL <br /> ALARMS. <br /> [_12. MONTHLY 0.2 GPH TEST ❑2. MONTHLY 0.2 GPH TEST <br /> ❑3. ANNUAL INTEGRITY TEST(0.1GPH) ❑3. ANNUAL INTEGRITY TEST(0.1GPH) <br /> 04. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all thatapply) <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM-TRIENNIAL PIPING INTEGRITY [15. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): [16. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> 07. SELFMONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW [17. SELF MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> ❑B. DAILY VISUAL MONITORING <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check one) <br /> ®a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> [31c. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM Ob <br /> DISCONNECTION <br /> AUTO PUMP <br /> SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION <br /> Oc. NO AUTO PUMP SHUT OFF [3c NO AUTO PUMP SHUT OFF <br /> ®11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUTOFF OR 11, AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> 012. ANNUAL INTEGRITY TEST(0.1 GPH) 012. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTIONIGRAVITY SYSTEM <br /> ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS 013. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF AUDIBLE AND ❑14. CONTINUOUS SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND <br /> VISUALALARMS <br /> ❑15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR [115, AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑16. ANNUAL INTEGRITY TEST(0.1 GPH) 016. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [117, DAILY VISUAL CHECK ❑17. DAILY VISUAL CHECK <br /> Vlll.DISPENSER CONTAINMENT <br /> DISPENSER Ell. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ®4.DAILY VISUAL CHECK <br /> CONTAINMENT <br /> DATEINSTALLED 468 ❑2. CONTINUOUS DISPENSER PAN SENSOR,AUDIBLE AND VISUAL ALARMS ❑5.TRENCH UNERI MONITORING <br /> ❑3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+ [1 6,NONE 469 <br /> AUDIBLE AND VISUAL ALARMS <br /> IX.OWNERIOPERATOR SIGNATURE <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> DATE 470 <br /> SIGN TUREOFOWNeR/OPaRATOR 3/17/00 <br /> ME O R/OP.�RP.TOR(print) TITLE OF OWNER/OPERATOR 472 <br /> Za a Gianino of RHL Design Grou , Inc. Agent for Tosco <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) Permit Expiration Date(For local use only) <br /> 475 <br /> UPCF (1/99 revised) Formerly SWRCB Form B <br />