My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4707
>
2300 - Underground Storage Tank Program
>
PR0231217
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:25:29 PM
Creation date
11/6/2018 9:15:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231217
PE
2361
FACILITY_ID
FA0003903
FACILITY_NAME
TOSCO CORPORATION #31258
STREET_NUMBER
4707
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10816004
CURRENT_STATUS
02
SITE_LOCATION
4707 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\4707\PR0231217\BILLING 1985-2000.PDF
QuestysFileName
BILLING 1985-2000
QuestysRecordDate
8/10/2017 7:03:02 PM
QuestysRecordID
3569249
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U D PROGRAM CONSOLIDATED FOR TANK <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> Page _3 of 5 <br /> VI. PIPING CONSTRUCTION(Oheckalltnat401) <br /> ABOVEGROUND PIPING <br /> UNDERGROUND PIPING459 <br /> ® <br /> SYSTEM TYPE 1.PRESSURE D 2.SUCTION ❑3.GRAVITY458 ❑1.PRESSURE ❑2. SUCTION ❑3.GRAVITY❑95.UNKNOWN462 <br /> CONSTRUCTION/ 01.SINGLE WALL ❑3.LINEDTRENCH ❑99.OTHER 460 1.0 2.SINGLEDOUBLE LL ❑99.OTHER WALL <br /> MANUFACTURER ®2.DOUBLE WALL D 95,UNKNOWN 463 <br /> MANUFACTURER 461 MANUFACTURER <br /> 1 BARE STEEL ❑6.FRP COMPATIBLE WI166%METHANOL <br /> D 1.BARE STEEL ®6.FRP COMPATIBLE W/100% METHANOL D 7,GALVANIZED STEEL <br /> ❑2 STAINLESS STEEL ❑7.GALVANIZED STEEL D 99 NOWN 2. STAINLESS STEEL <br /> O HER ❑3, PLASTIC COMPATIBLE WI CONTENTS D B.FLEXIBLE(HDPE) D 99. OTHER <br /> ❑3.PLASTIC COMPATIBLE WI CONTENTS ❑ ❑4, FIBERGLASS D 9.CATHODIC PROTECTION <br /> ❑4.FIBERGLASS D 8.FLEXIBLE(HDPE) D 95.UNKNOWN 465 <br /> D 5.STEEL WICOATING ❑9.CATHODIC PROTECTION <br /> 464 D5. STEEL WICOATING <br /> VII:PIPINCrLEAK DETECTION(Check all that appl ) Adescn lion of thet`m6nitorin program slialAIBOVEGROUNsubmitted to tD PIPINGlocal enc ).'. <br /> UNDERGROUND PIPING SINGLE WALL PIPING 467 <br /> SINGLE WALL PIPING ass <br /> PRESSURIZED PIPING(check all that apply): <br /> PRESSURIZED PIPING(Check all Ihatapp4l' <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VIAL <br /> ❑1 ELECTRONIC LINE <br /> LEAK DETECTOR <br /> RMDISCO TEST <br /> WITH <br /> ATO UMPSHVT OFF FOR R ❑1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH SU <br /> TEST WITH AUTO PUMP SHUTSOFF FOR <br /> U <br /> LEAK <br /> STEM <br /> AND <br /> E AND <br /> ALARMS. <br /> ALARMS. D2, MONTHLY 0.2 GPH TEST <br /> ❑2. MONTHLY 0.2 GPH TEST D 8, ANNUAL INTEGRITY TEST(O.IGPH) <br /> D3. ANNUAL INTEGRITY TEST(0.1GPH) ❑4, DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> CONVENTIONAL SUCTION SYSTEMS <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY D5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPINGj'. <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑7. SELF MONITORING D 7, SELF MONITORING <br /> GRAVITY FLOW GRAVITY FLOW(Check WI that apply): <br /> D9. BIENNIAL INTEGRITY TEST(0.1 GPH) D8, DAILY VISUAL MONITORING <br /> [19, BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. Check one) TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AN <br /> (Checkane) ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> Me. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS p AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> ❑b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION ❑c NO AUTO PUMP SHUT OFF <br /> Dc. NOAUTO PUMP SHUT OFF <br /> ®11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHFLOW SHUTOFF OR ❑11, AUTOMATIC LEAK DETECTOR <br /> RESTRICTION [112. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) SUCTIONIGRAVITY SYSTEM <br /> SUCTIONIGRAVITY SYSTEM ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> D 13. CONTINUOUS SUMP GEN SOR+AUDIBLE AND VISUAL ALARMS EMERGENCY GENERATORS ONLY(Check all that apply) <br /> EMERGENCY GENERATORS ONLY(Check all that apply) <br /> [114, CONTINUOUS SUMP SENSOR WITH AUTO PUMP SHUT OFF+AUDIBLE AND [114. VSUAINUOUSSALARMMP SENSOR WITHOUT AUTO <br /> PUMP SHUT OFF-AUDIBLE AN <br /> VISUALALARMS1-115, AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> D 15 AUTOMATICNE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR <br /> Dib. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> D 16. ANNUAL INTEGRITY TEST(0.1 GPH) D 17. DAILY VISUAL CHECK <br /> 1-1 IT DAILY VISUAL CHECK <br /> ' VIII:DISPENSER-0ONYAIN�IENT1a„� <br /> DISPENSER ®4,DAILY VISUAL CHECK <br /> CONTAINMENT ❑1 FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE <br /> DATE INSTALLED ase ❑2. CONTINUOUS DISPENSER PAN SENSOR AUDIBLE AND VISUAL ALARMS D 5.TRENCH LINER I MONITORING 469 <br /> D3. CONTINUOUS DISPENSER PAN SENSORWITH AUTO OFF FORDISPENSER+ D6 NONE <br /> AUDIBLE AND VISUAL ALARMS h <br /> IX.OWNER/OPElh TLV,SIGNATURE <br /> h9 _. 470 <br /> Icedfytha(lhe'mformation provided hereWn Ws true and accurate to the best of my knowledge. DATE <br /> SIG URE OF ER/OPERATOR 3/17/00 472 <br /> TITLE OF OWNER/OPERATOR <br /> NA O RIOPRATOR(print) q ant for Tosco <br /> Zai a Gianino of RHL Design GEOU Inc. permit Expi etion Date(For to el use only) <br /> Permit Number(For local use only) 473 Permit Approved(For Localuseonly) 475 <br /> Formerly SWRCB Form B <br /> UPCF(1/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.