EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4707
>
2300 - Underground Storage Tank Program
>
PR0231217
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:25:29 PM
Creation date
11/6/2018 9:15:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231217
PE
2361
FACILITY_ID
FA0003903
FACILITY_NAME
TOSCO CORPORATION #31258
STREET_NUMBER
4707
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10816004
CURRENT_STATUS
02
SITE_LOCATION
4707 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\4707\PR0231217\BILLING 1985-2000.PDF
QuestysFileName
BILLING 1985-2000
QuestysRecordDate
8/10/2017 7:03:02 PM
QuestysRecordID
3569249
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LIM ED PROGRAM CONSOLIDATED FOR TANK <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> Page 3 of 5 <br /> VI.PIPING CONSTRUCTION(Crack all that apPIY) <br /> ABOVEGROUND PIPING <br /> UNDERGROUND PIPING 459 <br /> *1,BARE <br /> E ®i.PRESSURE ❑2.SUCTION ❑3.GRAVITY 458 ❑1.PRESSURE 712. SUCTION 95.UNKNOWN 462 GRAVITY 462 <br /> ON 1 ❑i.SINGLE WALL ❑3.UNED TRENCH [199.OTHER 460 ❑i,SINGLE WALL ❑gg.OTHER <br /> RER ®2.DOUBLE WALL ❑95.UNKNOWN ❑2.DOUBLE WALL 463 <br /> MANUFACTURER 461 MANUFACTURER <br /> [16.FRP COMPATIBLE w/foosc MErHArvoL <br /> TEEL M 6.FRP COMPATIBLE w1190% METHANOL ❑1.BARE STEEL 7 GALVANIZED STEEL <br /> ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑UKNOWN Cl 2. STAINLESS STEEL ❑ <br /> ❑3.PLASTIC COMPATIBLE WI CONTENTS ❑99. OTHER [13. PLASTIC COMPATIBLE WI CONTENTS O 9.CATHIODIC PROLE BLE E)ECTDION9 OTHER <br /> ❑4. FIBERGLASS <br /> [14.FIBERGLASS ❑B.FLEXIBLE(HDPE) 95.UNKNOWN 465 <br /> ❑5,STEEL WICOATING D 9.CATHODIC PROTECTION 464 ❑5, STEEL WICOATING ❑ <br /> VII.PIPING LEAK DETECTION(Cneck ainhet app!". @sck'Gon o(iPH <br /> bgramshalALBbOVEGROUND PIsubmitted to the let 6,1 nc .) <br /> UNDERGROUND PIPING SINGLE WALL PIPING 467 <br /> SINGLE WALL PIPING 46fiPRESSURIZED PIPING(Check all thatapplyl: PRESNG(Check all that apply): <br /> 1. ELECTRONIC UNE LEAK DETECTOR3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑1' LEAKNESYSTEM LEAKK,ANDCTOEM DISCONNECTIONEST WITH AUAUUDIBE ANDPUMP UVISUALOR <br /> LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION.AUDIBE AND VISUAL ALARMS. ❑2, TEST <br /> ❑2. MONTHLY 0.2 GPH TEST <br /> [2 3, ANNUAL INTEGRITY TEST(0.1 GPH) ❑3. ANNUAL INTEGRITY TEST 10.iGPH) <br /> ❑4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply! <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM-TRIENNIAL PIPING INTEGRITY ❑5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) D6, TRIENNIAL INTEGRITY TEST Ol GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING)'. <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑7. SELF MONITORING [17. SELF MONITORING <br /> GRAVITY FLOW <br /> GRAVITY FLOW(snack al that apvlY): <br /> ❑9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑B. DAILY VISUAL MONITORING <br /> [19. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSORWITf AUDIBLE AND VISUAL ALARMS AND t0' CONTheck one) US TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check one) ❑a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> Na. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS 6 AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> ❑b AUTO PUMP DISCONNECTION T OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ DISCONNECTION <br /> ❑c. NOAUTO PUMP SHUT OFF <br /> [1c NO AUTO PUMP SHUT OFF <br /> Eli. AUTOMATIC UNE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUTOFF OR ❑11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION ❑12. ANNUAL INTEGRITY TEST(OA GPH) <br /> [112. ANNUAL INTEGRITY TEST(0.1 GPH) SUCTION/GRAVITY SYSTEM <br /> SUCTIONIGRAVITY SYSTEM <br /> ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13. CONTINUOUS SUMP SENSOR*AUDIBE ANOVISUALALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) <br /> EMERGENCY GENERATORS ONLY(Check all that apply) <br /> [3 14. CONTINUOUS SUMP SENSOR WITH AUTO PUMP SHUT OFF+AUDIBLE AND [114. V NTINU USS MP SENSOR WITHOUT AUTAL O PUMP SHUT OFF, AND <br /> VISUALALARMS <br /> ❑15. AUTOMATIC UNE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR [115. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION [116, ANNUAL INTEGRITY TEST(0.1 GPH) <br /> D16, ANNUAL INTEGRITY TEST(0.1 GPH) 017 DAILY VISUAL CHECK <br /> D 17. DAILY VISUAL CHECK <br /> VIII:.DISPENSER CGNTAINMENIt'lae„„ ' <br /> DISPENSER ®4.DAILY VISUAL CHECK❑5.TRENCH LINER)MONITORING <br /> CONTAINMENT D1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE <br /> DATE INSTALLED 460 [:12. CONTINUOUS DISPENSER PAN SENSOR-AUDIBLE AND VISUAL ALARMS x69 <br /> D3, CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+ [16.NONE <br /> AUDIBLE AND VISUAL ALARMS <br /> a- y, IX.:DANE R70PERATOR SIGNATURE <br /> I comity that the information provided herein is true and accurate to the best of my knowledge. 470 <br /> SIG URE OF ER/OPEF;P,TOR DATE <br /> 3/17/00 472 <br /> RATOR(print) TITLE OF OWNEFJOPERATOR <br /> NA O R/OP <br /> Zai a Gianino RA RRL Desi n Grou , InC.L.Inc. Agent for Tosco <br /> of <br /> Permit Expiration Cale(For Ideal use only) <br /> Permlt Number(For local use only) 473 Permit Approved(For local u eon ) 475 <br /> ormerly SVVRC9PFOrrn B <br /> UPCF (1199 revised) <br />