COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5151
>
2300 - Underground Storage Tank Program
>
PR0231219
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2020 5:53:44 PM
Creation date
11/6/2018 9:19:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231219
PE
2381
FACILITY_ID
FA0002836
FACILITY_NAME
SAN JOAQUIN DELTA COLLEGE DIST
STREET_NUMBER
5151
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10816001
CURRENT_STATUS
02
SITE_LOCATION
5151 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\5151\PR0231219\COMPLIANCE INFO 1987-2015.PDF
QuestysFileName
COMPLIANCE INFO 1987-2015
QuestysRecordDate
8/15/2017 3:06:13 PM
QuestysRecordID
3580045
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PREISM <br /> INDUSTRIES <br /> 1041 S. PERShiING AVE., STOCKTQN, CALIFORNIA 95206 <br /> 2091462-9911 NO. CALIF. 8001332-5900 <br /> CA L1FCHNIA STATE LIC.467293 <br /> INt; <br /> OCTOBER 17, 1988 <br /> '4ff� {7 JI <br /> SAN JOAQUIN DELTA COLLEGE <br /> 5157E PACIFIC AVENUE 19� <br /> SI'OCK`IION, CA 95207 <br /> p,5RMlr����,,�,r;� �_ t`',I <br /> AT ENITION: TONI CARDINALE <br /> LOCATION: SAME AS ABOVE <br /> RESULTS OF TANK TESTS PERFOFdM OCTOBER 10, 1988 <br /> TANK #1 - 1,000 gallon diesel fuel tank - <br /> Full system test indicated a volume change of <br /> -.0012 gallons per hour under test conditions. <br /> Full system test is within state guidelines. <br /> TANK #2 - 1,000 gallon unleaded fuel tank - <br /> Full system test indicated a volume change of <br /> -.0039 gallons per hour under test conditions. <br /> Full system test is within state guidelines. <br /> TANK #3 - 2,000 gallon regular fuel tank - <br /> Full system test indicated a volume change of <br /> -.0088 gallons per hour under test conditions. <br /> Full system test is within state guidelines. <br /> PRECISION INDUSTRIES, INC. <br /> NICK CLAYTON <br /> TANK TEST COORDINATOR <br /> NCI}w <br /> Enc. <br />