My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5151
>
2300 - Underground Storage Tank Program
>
PR0231219
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:36:09 PM
Creation date
11/6/2018 9:25:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231219
PE
2381
FACILITY_ID
FA0002836
FACILITY_NAME
SAN JOAQUIN DELTA COLLEGE DIST
STREET_NUMBER
5151
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10816001
CURRENT_STATUS
02
SITE_LOCATION
5151 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\5151\PR0231219\BILLING 1985-2001.PDF
QuestysFileName
BILLING 1985-2001
QuestysRecordDate
8/15/2017 3:29:37 PM
QuestysRecordID
3580432
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI ft WATER RESOURCES CONTRt�ARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PRO RAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ I NEW PERMIT F-13 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE [5:j 8 TANK REMOVED c.Y� <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: �= = 1 i;(-, FARM TANK-YES❑ NO <br /> i <br /> 0 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ID N - MNFACTURED BY: W <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> 0 <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A1),IS NOT MARKED,COMPLETE ITEM 0. CA <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. [::] I UNLEADED ❑2 LEADED ❑3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS E] 80 EMPTY [—]95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.N C.A.S.N: <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A B,C,&D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARf CONTAINMENT ❑99 OTHER <br /> ❑ I STEEUIRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIOE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHEfl <br /> ❑ <br /> C. INTERIOR 1 RUBBERUNED ❑ 2 ALKYD LINING ❑3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑ ISLINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TARORASPHALT ❑3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U I SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U..91.NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELPRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 5 CONCRETE AU 7 STEELGLADW/FRP A U 8 /00%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED, <br /> P 8 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P 8 6 PRECISION TESTING P 8 1 PRESSURE TESTING P S 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY M JURISDICTION B AGENCY I FACILITY ID B TANK ID R <br /> ) I � I I I I ` <br /> 5� CURRENT LOCAL AGENCY FACILITY 10I APPROVED BY NAME PHONE I WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CNECKI PERMIT AMOUNT SURCHARGE ANT. FEE CODE RECEIPTI BY: <br /> AIML -T <br /> FORM a(e zaee)CHECKI -7�THIS FORM MUST BE ACCOMPANIED AGILITY/SITE APPLICATION, FORM 'A',UNLESS A Cl <br /> ..,NT FORMA' HAS BEEN FILED <br /> V� DATA PROCFSSIM^ r n" <br />
The URL can be used to link to this page
Your browser does not support the video tag.