My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5151
>
2300 - Underground Storage Tank Program
>
PR0231219
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:36:09 PM
Creation date
11/6/2018 9:25:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231219
PE
2381
FACILITY_ID
FA0002836
FACILITY_NAME
SAN JOAQUIN DELTA COLLEGE DIST
STREET_NUMBER
5151
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10816001
CURRENT_STATUS
02
SITE_LOCATION
5151 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\5151\PR0231219\BILLING 1985-2001.PDF
QuestysFileName
BILLING 1985-2001
QuestysRecordDate
8/15/2017 3:29:37 PM
QuestysRecordID
3580432
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIfS WATER RESOURCES CONTRO ARD <br /> FORM 'S': UNDE ROUND STORAGE TANK PRO AM f <br /> /AI <br /> TANK PERMIT APPLICATION INFORMATION <br /> TANK INFORMATION FOR EACH TANK <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFO O O H <br /> MARK ONLY ❑ I NEWPERMIT ❑ 3 RENEWALPERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑A AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑'8 TANK REMOVED <br /> FACILITY/BITE NAME WHERE TANK IS INSTALLED: . ` - / - FARM TANK-YES❑ NO <br /> •0 <br /> I. TANKOESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK IDK `"7 B. MANUFACTURED BY: W <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: ^Y <br /> d <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ A OIL ❑ 1PRODUCT ❑ #GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> El5 HAZARDOUS ❑ 80 EMPTY [:]95 UNKNOWN El2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED h C.A.S.K C.A.S.p: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑R SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ I STEELIIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑1 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑S CONCRETE ❑6 PDLYVIWLCHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ IB GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> ❑ <br /> C. INTERIOR I RUBBERLINED ❑2 ALKYDUNING ❑ 3 EPDXYLINING ❑1 PHENOLIC UNING <br /> ' LINING ❑ 5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑ ISLINING MATERIAL COMPATIBLE WITH IW%METRANOL7 E]YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ I POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑3 VINT.WRAP ❑ /FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ S CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U I SINGLE WALLED A U 2 COUPLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U I STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U H FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U B CONCRETE A' V 7 STEEL CLAOW/FRP A U R 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P ! I VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P 6 5 GROUND WATER MONITORING WELLS <br /> P S 0 PRECISION TESTING P S 1 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL7 [:]YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED A SIGNATURE) DATE <br /> L <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION K AGENCY K FACILITY ID K TANK IO# <br /> i <br /> CURRENT LOCAL AGENCY FACILITY ID/ APPROVED BY NAME PHONE I WITH AREA CODE <br /> 41 <br /> PERMIT NUMBER PERMIT APPROVAL DATE JPENMIT EXPIRATION DATE v <br /> ' CHECK# PERMIT AMOUNT SURCHARGE AMT. <br /> FEE CODE RECEIPT) BY. <br /> •,�-� FORM B(6.2mB) THIS FORM MUST BE ACCOMPANIED CILITY/SITE APPLICATION, FORM 'A',UNLESS A CU1q.rkT FORMA' HAS BEEN FILED <br /> I <br /> DATA PnnrccclMn nn•+.• <br />
The URL can be used to link to this page
Your browser does not support the video tag.