BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5151
>
2300 - Underground Storage Tank Program
>
PR0231219
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:36:09 PM
Creation date
11/6/2018 9:25:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231219
PE
2381
FACILITY_ID
FA0002836
FACILITY_NAME
SAN JOAQUIN DELTA COLLEGE DIST
STREET_NUMBER
5151
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10816001
CURRENT_STATUS
02
SITE_LOCATION
5151 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\5151\PR0231219\BILLING 1985-2001.PDF
QuestysFileName
BILLING 1985-2001
QuestysRecordDate
8/15/2017 3:29:37 PM
QuestysRecordID
3580432
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN18 WATER RESOURCES CONTR(SOARD :y4". •;'~r�A <br /> FORM 'B': UNDERGROUND STORAGE TANK PRO RAM u wo <br /> TANK TANK PERMIT APPLICATION INFORMATION ® µ <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> I� <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> CTI <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED. y + FARM TANK-YES❑ NO r,-) <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY [� <br /> A. OWNERS TANK ID 4 ' B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: lom <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. �1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED E] 2 LEADED 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL E�l PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ BO EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C,A,S.#: <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM K2 SINGLE WALLEO ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> STEEL/IRON ❑ 2 STAINLESS STEEL F-] 3 FIBERGLASS ❑ 4 STEEL CLAD WIFIBERGLASSREINFORCED PLASTIC <br /> B.TANK 65 <br /> CONCRETE ❑ 6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> El RUBBER LINED [:] 2 ALKYD LINING ❑ 3 EPDXY LINING E] 4 PHENOLIC LINING <br /> C. INTERIOR <br /> LINING ®5 GLASS LINING F17 6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑ YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION E:51 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMA CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A 1 UCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION LW SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINEDTRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U STEELIIRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECT 10 NLSYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 1 VISUAL CHECK P 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1, ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> EPERMITNUMBER <br /> JURISDICTION# AGENCY# FACILITY ID#L-LI-772- LHL <br /> TANK ID# <br /> [Ml I <br /> A^G,ENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT APPROVAL DATE PERMIT EXPIRATION DATEPERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY:, Y! <br /> FORMS(6-29-88) THIS FORM MUST BE ICCOMPANIE Y A FACILITYISITE APPLICATION, FORM `A',UNLESS A I;IIRRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />