Laserfiche WebLink
BOARO OF TRUSTEES SAN JOAQUIN LOCAL HEALTH DISTRICT SERVING <br /> James Culbenson, Pres. <br /> City of Lodi <br /> A nihonell <br /> Patricia Vannuccl, Secy. 1601 East Hazelton Avenue, P. O. Box 2009 Sen Joaquin County <br /> tte Ven Spronsen City of Eacelon <br /> Earl Plmenlel Stockton, California 95201 _ -City of Manteca <br /> Fern Bugbee 209/466-6781 City of Ripon <br /> Daniel L. Flores City of Stockton <br /> John 0. Meal, M.D. City of Tracy <br /> William J. Wade Jopl Khanna, M.O., M.P.M., District Health Officer San Joaquin County <br /> Mary Anna Love San Joaquin County <br /> Facility Name <br /> Address Sl�� / �GCFZ G L}1f� S7�G✓� Gf� pS2�1 <br /> Date of Inspection Inspector G✓ <br /> MONITORING ALTERNATIVE #7 <br /> Limited to undernround storage tanks which have infrequent inputs and withdrawals and <br /> where the liquic, level in the tank can be measured to an accuracy of +5 gallons or less <br /> when the tank is half full . <br /> This�nitoring alternative shall include: <br /> nnual precision test on tank and piping. <br /> V Tank gauging performed as follows: <br /> Tank must be capable of being secured to prevent unauthorized inputs and <br /> withdrawals. <br /> Tank must have no inputs or withdrawals for at least a 48 hour period <br /> (2 days) at the end of consecutive periods lasting up to 7 days. <br /> (For example: tank in use Monday through Friday, then locked <br /> over weekend) . <br /> V/ Liquid level measurements are taken at the beginning and end of the <br /> monitoring period (lasting at least 48 hours). <br /> (For example: level measured and recorded Friday night before <br /> / locking and again on Monday morning before opening. ) <br /> V If liquid level varies more than 1% of the tank volume or 5 gallons , which <br /> ever is less , between measurements , an unauthorized release shall be <br /> assumed to have occurred and shall be reported to the local agency within <br /> 24 hours , as per Article 5, Sect. 2652 of the regulations and further <br /> evaluations shall be performed to verify or disprove the variations. <br /> Implementation of the monitoring alternative requires that the following circled items be <br /> com leted by the dates specified. <br /> Precision test(s) must be performed by and results submitted to this <br /> office within 30 days of the test. <br /> Tank gauging must be started immediately. (See instructions above), <br /> If the above compliance dates cannot be met, contact this office prior to the specified <br /> date. <br /> 4/86 UGT 3 <br />