My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1996-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7647
>
2300 - Underground Storage Tank Program
>
PR0231227
>
BILLING 1996-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:09 AM
Creation date
11/6/2018 9:53:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1996-2005
RECORD_ID
PR0231227
PE
2361
FACILITY_ID
FA0004033
FACILITY_NAME
BEST CALIFORNIA GAS LTD #172
STREET_NUMBER
7647
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
07748014
CURRENT_STATUS
02
SITE_LOCATION
7647 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\7647\PR0231227\BILLING 1996-2005.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
{ <br /> WIFIED PROGRAM CONSOLIDATED IsmSITE#2705449/05449 <br /> gUr� PIPING <br /> UNDERGROUND STORAGE TANKS - TANK PAGE <br /> VI.PIPING CONSTRLCTION(eheakall ebmpply) Page of <br /> SYSTEM TYPE .PRESSURE 0 <br /> 2.SUCTION ❑3.GRAVITY 458 ❑I.PRESSURE <br /> ❑ 1 SINGLE W <br /> 3.LINED TRENCH ALL ❑ [199.OTHER 460 ❑2.SUCTION E13.GRAVITY 459 <br /> CONSTRUCTION/ ❑95.XERXES ❑1.SINGLE WALL [195.XERXES 462 <br /> MANUFACTURER 2.DOUBLE WALL E:12.DOUBLE WALL [199.OTHER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> Eli BARE STEEL 06.FRP COMPATIBLE you.METHANOL [It.BARE STEEL ❑6.FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL 07.GALVANIZED STEEL <br /> CORROSION ❑3. LASTIC COMPATIBLE WITH CONTENTS 095.XERXES ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑8.FLEXIBLE(HDPE) 099.OTHER <br /> PROTECTION IT5KZIBERGLASS 08.FLEXIBLE(HDPE) E399.OTHER ❑4. FIBERGLASS ❑9.CATHODIC PROTECTION <br /> 5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5. STEEL W/COATING ❑95. XERXES 465 <br /> VII.PIPING LEAK DETECTION(cheak an that apply)(A deerriptice ojthe tnoniroring pWgrom shall besubmitted to the Iwai agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ I. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TESTMM AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST YM AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 2, MONTHLY 0.2 GPH TEST <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Chak all that apply): <br /> ❑ 5 DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST E)I GPH) ❑ 6. TRIENNIAL.INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING). <br /> ❑ 7 SELFMONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW GRAVITY FLOW(Cheakall that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIA.INTEGRITY TEST IDA GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING PRESSURIZED PIPING(Cheek all that app/y): <br /> PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WIT F AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) ❑ u. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ e. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ c. NO AUTO PUMP SHUT OFF <br /> DISCONNECTION ❑ 11. AUTOMATIC LEAK DETECTOR <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST))M FLOW SHUT OFF OR <br /> RESTRICTION '11 nn� SUCTION/GRAVITY SYSTEM: <br /> 12, ANNUAL INTEGRITY TEST in 1 GPH) - N�WI�I K4.S. ❑ 13. CONTINUOUS SUMP SENSOR AUDIBLE AND VISUAL ALARMS <br /> SUCTION/GRAVITY SYSTEM: EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 14. CONTINUOUS SUMP SENSORTH <br /> l�V SIL[AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> ALARMS <br /> EMERGENCY GENERATORS ONLY(Check./l that apply) ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑ 14. CONTINUOUS SUMP SENSOR SITTHOL AUTO PUMP SHUTOFF-AUDIBLE AND <br /> VISUAL ALARMS ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ I5. AUTOMATIC LME LEAK DETECTOR(3.0 GPH TEST)MT O FLOW SHUT OFF OR ❑ 17 DAILY VISUAL CHECK <br /> RESTRICTION <br /> ❑ 16 ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17 DAILYVISUALCHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT L FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE El <br /> 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WI Ty AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6.NONE 469 <br /> IX.OWNER/OPERITOR SIGNATURE <br /> 1 certify that the infermation provided herein u we and accurate to the best afro,knowledge. <br /> SI A REOFO OPERATOR DATE ' .Au 470 <br /> NAMED WNER/OPERATOR ri®I 471 TITLEOFO OPERATOR 472 <br /> JANE VE M.THOMPSON FOR CIRCLE K STORES,INC. COMPLIANCE SPECIALIST <br /> Penin Number(For local use only) 473 Pmmt Approved(For local we only) 474 1 Pemdt Expiration Date(For local use a,,I,)475 <br />
The URL can be used to link to this page
Your browser does not support the video tag.