My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1996-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7647
>
2300 - Underground Storage Tank Program
>
PR0231227
>
BILLING 1996-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:09 AM
Creation date
11/6/2018 9:53:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1996-2005
RECORD_ID
PR0231227
PE
2361
FACILITY_ID
FA0004033
FACILITY_NAME
BEST CALIFORNIA GAS LTD #172
STREET_NUMBER
7647
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
07748014
CURRENT_STATUS
02
SITE_LOCATION
7647 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\7647\PR0231227\BILLING 1996-2005.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OIFIED PROGRAM CONSOLIDATED OMSITE C,2 <br /> 705449/05449PIPING <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 5 iyL�w <br /> VL PIPING CONSTRLCTION(cheekal/matapply) Page _ of <br /> AROVEGROUND PIPING <br /> SYSTEM TYPE ,PRESSURE E12.SUCTION [13.GRAVITY 458 ❑1.PRESSURE 02.SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION/ ❑1.SINGLE WALL El 3.LINED TRENCH [199.OTHER 460 E]1.SINGLE WALL [195.XERXES 462 <br /> W.MANUFACTURER DOUBLE WALL El95.XERXES E12.DOUBLE WALL E199.OTHER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> El 1.BARE STEEL 06.FRP COMPATIBLE W,i00w METHANOL ❑LBAAE STEEL ❑6.FEE COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> CORROSION ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑95.XERXES ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑S.FLEXIBLE(HDPE) 099.OTHER <br /> PROTECTION .FIBERGLASS ❑8.FLEXIBLE(HDPE) E199.OTHER ❑4. FIBERGLASS 09.CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5. STEEL W/COATING ❑95. XERXES 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description ofthe mannoring program shall be submitted to the local agaaey) <br /> SINGLE WALL PIPING SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Cheek all that apply): <br /> ❑ I. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 2. MONTHLY 0.2 GPH TBET <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 3. ANNUAL C TEST(0A GPH) <br /> El 4. DAILY VISSUALUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS(Check a4 that apply): <br /> CONVENTIONAL DAILY VISUAL TION <br /> ❑ 5. DAILY VISUALMONITORING OFPIPINGAND PUMPING SYSTEM <br /> ❑ 5 DAILY VISUAL MONITORING OF PUMPING EYSTEM+TRIENNIAL PIPING INTEGRITY <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING) <br /> ❑ 7 SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW GRAVITY FLOW(Check tall that apply). <br /> ❑ 9 BIENNIAL INTEGRITY TEST(0 I GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0 I GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING PRESSURIZED PIPING(Check all,hat apply): <br /> PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check oae) ❑ o AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ Is. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> Is, AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ c. NO ACRO PUMP SHUT OFF <br /> DISCONNECTION ❑ 11, AUTOMATIC LEAK DETECTOR <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ 12. ANNUAL INTEGRITY TEST(0,1 GPH) <br /> I AUTOMATIC LIVE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTIONf n�'!''�Q SUCDON/GRAVITY SYSTEM: <br /> 12. ANNUAL INTEGRITY TEST(0.1 GPH) µ <br /> - EW I� 5. ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> SUCTION/GRAVITY SYSTEM: EMERGENCY GENERATORS ONLY(Checka//that apply) <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 14. CONTINUOUS SUMP SENSOR 3DIMU AUTO PUMP SHUTOFF+AUDIBLEANDVISUAL <br /> ALARMS <br /> ❑ I5 <br /> EMERGENCY GENERATORS ONLY(Cherkall that apply) . AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑ I4. CONTINUOUSSUMPSENSORWITHO AUTO PUMP SHUT OFP+pIIDIBLH AND <br /> VISUAL ALMUAS <br /> 16, ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHO FLOW SHUT OFF OR ❑ 17. DALLY VISUAL CHECK <br /> RESTRICTION <br /> ❑ 16. ANNUAL MTEGRITY TEST(0.1 GPH) <br /> ❑ 17 DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT L FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 466 ET2.CONTINUOUS DISPENSER PAN SENSOR.AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LMR/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6.NONE 469 <br /> IX.OWNER/OPERITOR SIGNATURE <br /> I certify that the information provided herein 1s we and accumtc to the but ofmy knowledge. <br /> EIG A RE OFO OPERATOR,P- DATE 470 <br /> 13 2t�oa. <br /> NAME 0 R/OPERATO (prinq 471 TITLE OF OWN OPERATOR 472 <br /> JANETTE M.THOMPSON FOR CIRCLE K STORES,INC. COMPLIANCE SPECIALIST <br /> Permit Number(For local use any) 473 Pend:Approved(Forlocal use only) 474 Pemdt Eepbstim.Date(For local use only)475 <br />
The URL can be used to link to this page
Your browser does not support the video tag.