COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7647
>
2300 - Underground Storage Tank Program
>
PR0231227
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/6/2018 10:00:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231227
PE
2361
FACILITY_ID
FA0004033
FACILITY_NAME
BEST CALIFORNIA GAS LTD #172
STREET_NUMBER
7647
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
07748014
CURRENT_STATUS
02
SITE_LOCATION
7647 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\7647\PR0231227\COMPLIANCE INFO 2006-2012.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> I►Tanknoh3W <br /> 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2241497 <br /> TEST TATE: 06 AUSTIN,TEXAS 78759(512)451-6334 <br /> CLIENT: CIRCCLELE K K STORES SITE: CIRCLE K #270544.9, CO. 123 <br /> _ TANKarNFORMATION . <br /> Tank ID: SUPER 1 Tank manifolded: NO Bottom to top fill in inches: 159.0 <br /> Product: SUPREME Vent manifolded: No Bottom to grade in inches: 170.0 <br /> Capacity in gallons: 11,849 Vapor recovery manifolded: YES Fill pipe length in inches: 39.0 <br /> Diameter in inches: 120.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 245 Overspill protection: YES Stage 1 vapor recovery: DUAL <br /> Material: DW FIBERG Installed: ATG Stage 11 vapor recovery: BALANCE <br /> CP installed on: <br /> COMMENTS <br /> 7 777-7q <br /> ... �: <br /> -- <br /> TAIVK-TEST RESUI.TS4 T st l4tl ttt ti. :- LHAK-pETECTOR TEST RESULTS,. ... Te t t d ., <br /> PSI at tank bottom: New/passed Failed/replaced Newlpassed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: FE PETRO <br /> Fluid volume in gallons: Model: t4Ln <br /> Tank water level in inches: Sft Uaxaaan Lz <br /> Test time: NOT Open time in soc: 4.00 <br /> Number of thermisters: TESTED Holding psi: 16 NOT <br /> Specific gravity: Resiliency cc: 140 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by (method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> UL LAGS TEST RESU.LTSTest-Metho��. <br /> LINE AL' <br /> LINE TEST RESULTS Test type <br /> Test time: Material: DW FIBERG <br /> Ullage volume: Diameter(in): 2.0 <br /> Ullage pressure: Length (ft): 150.0 <br /> Results: Test psi: <br /> Bleedback cc: <br /> DATA FOR UTS4T ONLY: Test time (min): <br /> Test 1:Start time: <br /> Time of test 1: Finish psi: NOT NOT NOT NOT <br /> Temperature: NOT Vol change cc: TESTED TESTED TESTED TESTED <br /> Test 2:Start time: <br /> Flow rate(cfh): TESTED Finish psi: <br /> Time of test 2: Vol change cc: <br /> Test 3:Start time: <br /> Temperature: Finish psi: <br /> Flow rate (cfh): Vol change cc: <br /> Time of test 3: Final gph: <br /> Temperature: Result: <br /> Flow rate(cfh): Pump type: PRESSURE <br /> COMMENTS Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: UNKNOWN <br /> Printed 03/22/2006 07:48 SBOWERS <br />
The URL can be used to link to this page
Your browser does not support the video tag.