My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7647
>
2300 - Underground Storage Tank Program
>
PR0231227
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/6/2018 10:00:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231227
PE
2361
FACILITY_ID
FA0004033
FACILITY_NAME
BEST CALIFORNIA GAS LTD #172
STREET_NUMBER
7647
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
07748014
CURRENT_STATUS
02
SITE_LOCATION
7647 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\7647\PR0231227\COMPLIANCE INFO 2006-2012.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITWING SYSTEM CERTIFITION <br /> se By All Jurisdictions Within the State of Caiifom <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3 Title 23, ffornia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitorinQ, system control anal by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The ovmerloperalor must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A General Information <br /> Facility Name: CIRCLE K#2705449,CO. 123 City: STOCKTON CA Zip:95207 <br /> Site Address: 7647 PACIFIC AVE Contact Phone No: 952-4515 <br /> Date of Testing/Service: 03/0912006 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:VRTLS350 Work Order Number: 2241497 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1-91 Tank ID: 2-89 <br /> X In-Tank Gauging Probe. Model: MAG 1 X In-Tank Gauging Probe. Model: MAG 1 <br /> X Annular Space or Vault Sensor. Model: 794380-301 Annular Space or Vault Sensor. Model: 794380-301 <br /> X Piping Sumpfrrench Sensor(s). Model: 208 Piping Sumprrrench Sensors). Model: 208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: MLD Mechanical Line Leak Deteclor, Model: LD2000 <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: Tank ID: <br /> X in-Tank Gauging Probe. Model: MAG 1 In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 794380-301 Annular Space or Vault Sensor. Model: <br /> X Piping Sumpfrrench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector, Model: LD2000 Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank OverfilliHigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> ispenser : 112 Dispenser ID: 314 <br /> MDispenser Containment Sensor(s) Model: 208 :X:l Dispenser Containment Sensor(s) Model-208 <br /> XQ Shear Valve(s). X Shear Valve(s) <br /> ❑Disponser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: <br /> RI Dispenser Containment Sensor(s) Model:208 Dispenser Containment Sensor(s). Model: <br /> RI Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser lD: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> ' If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspectedlserviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up Alarm history report <br /> r <br /> Technician Name(print): ROBERT SANTOS Signature: <br /> Certification No.: 5254122 License. No.: <br /> Testing Company Name:Tan knology Phone No.: (800)800-4633 <br /> Site Address: 8501 N. MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 03/09/2006 <br /> Page 1 of 3 Based on CA form dater. <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.