COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7647
>
2300 - Underground Storage Tank Program
>
PR0231227
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/6/2018 10:00:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0231227
PE
2361
FACILITY_ID
FA0004033
FACILITY_NAME
BEST CALIFORNIA GAS LTD #172
STREET_NUMBER
7647
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
07748014
CURRENT_STATUS
02
SITE_LOCATION
7647 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\7647\PR0231227\COMPLIANCE INFO 2006-2012.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
X <br /> b. Results of Testing/Servicing <br /> Software Version Installed: <br /> Complete file following checklist: <br /> Yes ❑ No* I Is the audible alarm operational? <br /> R Yes ❑ No* Is the visual alarm operational? <br /> 23 Yes ❑ No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> Jff Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> NIA operational? <br /> Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> �e2 ❑ NIA monitoring system detects a leak, fails to ope te, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) '5LSump/Trench Sensors; ;k Dispenser Containment Sensors. } <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ❑Yes; 9NO. ✓jse-fZ <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (ie. no <br /> NIA mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill oint s and operating ro erl If so,at what percent of tank capacity does the alarm trigger? °/a <br /> ❑ Yes* ,IS( No Was any monitoring equipment replaced? If yes,identify specific sensors,,probes,or other equipment replzced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* U1 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that appty) ❑ 1 <br /> Product; ❑Water. If yes,describe causes in Section E,below. <br /> Yes Cl No* Was monitorin system set-ureviewed to ensure proper settings?Attach set up re orts,if applicable <br /> ,A Yes I ❑ No* Is all monitoring a ui mentoperational per manufacturer'sspecifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments. <br /> Page 2 of f_GI <br />