My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7647
>
2300 - Underground Storage Tank Program
>
PR0231227
>
BILLING 2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:09 AM
Creation date
11/6/2018 10:03:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2006-2008
RECORD_ID
PR0231227
PE
2361
FACILITY_ID
FA0004033
FACILITY_NAME
BEST CALIFORNIA GAS LTD #172
STREET_NUMBER
7647
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
07748014
CURRENT_STATUS
02
SITE_LOCATION
7647 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PACIFIC\7647\PR0231227\BILLING 2006-2008.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�IFIED PROGRAM CONSOLIDATED FOR TANK: TA0505680 <br /> PR#: PR0231227 <br /> FAC#: FA0004033 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 12,1131o) vtV1.PIPING CONSTRUCTION(ChFk.11 dlm.pph,) P sen <br /> DNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE 91PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 45e <br /> ❑ I.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 459 <br /> CONSTRUCTION ❑1.SINGLE WALL ❑3.LINED TRENCH ❑ 99.OTHER 4W ❑ 1.SINGLE WALL ❑ 95.UNKNOWN 063 <br /> ®2.DOUBLE WALL 095.UNKNOWNEl2.DOUBLE WALL C1 ",OTHER 463 <br /> 461 <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL ❑6.FRP COMPATIBLE w/IW..WTHANOL ❑ 1.BARE STEEL [-16,FRP COMPATIBLE n/IOU"/.METHANOL <br /> ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> F1 PLASTIC COMPATIBLEW/CONTENTS [:] 95.UNKNOWN F] PLASTIC COMPATIBLE W/CONTENTS <br /> El 95.UNKNOWN <br /> M 4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ W.OTHER ❑4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER <br /> ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑9.CATHODIC PROTECTION 465 <br /> VI.PIPING LEAK DETECTION(clack all wt apph)(A,on,,,,nier.fiken atirmnig,ro,arn shall x submklai o ma lecal agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check ell that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR) ,,SYSAL TEM FAILURE,AND SYSTEM DISCONNECTION'AUDIBLE AND <br /> VISUAL ALARMS. <br /> ❑ 2.MONTHLY 0.2 GPH TEST ❑2.MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> CONVENTIONAL SUCTION SYSTEMS ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> ❑ 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING <br /> INTEGRITY TEST(0.1 GPH) ❑ 6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> ❑ 7.SELF MONITORING ❑ 7.SELF MONITORING <br /> GRAVITY FLOW GRAVITY FLOW(Check all that apply): <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> ❑ e.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(clackaa) ALARMS AND(Cluck one) <br /> ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> M b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ® 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all thin-111) EMERGENCY GENERATORS ONLY(C krill metapph) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF• ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF' <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW E] I5.AUTOMATIC LINE LEAK DETECTOR Ci 0 GPH TEST)WITHOUT FLOW <br /> ❑ SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ® 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ® I.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑ 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6.NONE 469 <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> LY.OWNER/OPERATOR SIGNATURE <br /> i emtifv IM10w Inforeancepravided hmin is we and accumm Ia dm ben pinry kno,Hedge. <br /> 470 <br /> SIGNATURE OF OWNER/OPERATOR DATE <br /> NAME OF OWNER/OPERATOR(print) 411 TITLE OF OWNER/OPERATOR 473 <br /> JANETTE M THOMPSON COMPLIANCE SPECIALIST <br /> Pemdt Numen(For legal use only) 473 ft.r A,.,a (For lochia.only) 474 Pamh E�pwtian D.te(Fmleeal mconlc) 475 <br /> PT0013192 <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.