My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PELTIER
>
7099
>
2300 - Underground Storage Tank Program
>
PR0504637
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 2:39:25 PM
Creation date
11/6/2018 10:13:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504637
PE
2332
FACILITY_ID
FA0006267
FACILITY_NAME
WHITNEY FARM
STREET_NUMBER
7099
Direction
E
STREET_NAME
PELTIER
STREET_TYPE
RD
City
ACAMPO
Zip
95220
CURRENT_STATUS
02
SITE_LOCATION
7099 E PELTIER RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PELTIER\7099\PR0504637\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
10/16/2017 11:24:30 PM
QuestysRecordID
3683825
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN16 WATER RESOURCES CONTR&OARD <br /> FORM 'S': UNDERGROUND STORAGE TANK PROGRAM P= <br /> TANK TANK PERMIT APPLICATION INFORMATION o <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING NFORMATION FOR EACH TANK. <br /> 10 <br /> 1 NEW PERMIT 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION <br /> MARK ONLY F-1 ❑ 7 PERMANENTLY CLOSED T❑ <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT n ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED 1 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 0 C • }' FARM TANK-YES 2fr NO ❑ N <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY W <br /> O <br /> A. OWNERS TANK ID# Q B. MANUFACTURED BY: IA--X- W <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: Dd D <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A7),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY 95 UNKNOWN ❑ 2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAMEOF I <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: N A <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A B,C,&D <br /> A TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM SINGLEWALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 MEL CUD W/RBFRGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8100%METHANOLCOMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR F-11 RUBBERLINED 2 ALKYD LINING F--] 3 EPDXY LINING E]4 PHENOLIC UNING <br /> LINING ❑5 GLASS LINING 6 UNUNED ❑ 95 UNKNOWN�fy w/�' .�/ <br /> [:] IS LINING MATERIAL COMPATIBLE WITH 1011%METHANOL? ❑YES ❑ NO ©OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TARORASPHALT ❑ 3 V15L WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A5 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM AP6 CONCRETE A U 7 STEELCLADW/FRP A U .8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> _)y, P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION S 3 VAD08E WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 1 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTI ATED DATE LAST USED(MO/YR) 2. ESTIMA ED QUANTITY OF 3.WAS NK FILLED WITH <br /> SU 5 NCE REMAINING IN J(1ATERIAL? ❑YES ❑ NO <br /> ^1 GALLONS 4 <br /> T IS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL A ENCY FACILITY ID k APPROVED BY NAME PHONE#WITH AREA CODE <br /> 7 <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXIIIRAYION DATE <br /> CHECKM PERMITAMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.