COMPLIANCE INFO 2012 - 2014
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2012 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 2:11:02 PM
Creation date
11/6/2018 10:35:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2014
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2012 - 2014 .PDF
QuestysFileName
COMPLIANCE INFO 2012 - 2014
QuestysRecordDate
12/8/2016 9:18:09 PM
QuestysRecordID
3274874
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.oro/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> FacilityYRC Inc/ Yellow Freight FaD"� 1535 East Pescadero Ave, Trac Inspection <br /> Name. g y Mar 3, 2014 <br /> Atltlress: Date: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal_Regulabms <br /> C1=Class 1 violation;C2=Class 2 violalion;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity,piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 1 1 10ther: See atlac tied"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Com <br /> UST Inspection: Routine & Annual Monitoring System Certification <br /> 303 & 315. The Truck Wash sump sensor VR 205, monitored by the monitoring panel Veeder-Root TLS <br /> 250i, was raised approximately six inches off the lowest point of the sump and not located to detect a <br /> leak at the earliest opportunity. Sump was found to have approximately half cup of water at the bottom of <br /> the saddle, beneath the hanging sump sensor. Wiring of the sump sensor was wrapped around the <br /> electrical box to shorten its wire to allow sensor to hang. <br /> -Work order C-130710, dated 11/08/13 by technician Charles, stated 'Soap L2 Alarm' & 'fix sensor in <br /> sump & cleared alarm'. Unclear what 'fix sensor' means. <br /> - Site map, date 11/16/13, by Jesus Reyes, water & rags in drum. Water was removed from several <br /> sumps. 12oz of water was found in soap STP sump. <br /> -Work order W-284844, dated 11/21/13 by technician Wayne, stated 'Soap tank: 2a fuel alarm (STP <br /> sump). ... Set clock to correct time & re-placed sensor at lowest point in sump.' <br /> Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. <br /> Immediately relocate this sensor to the lowest point of the soap sump. To avoid water intrusion into the <br /> sump, ensure the area around the sump collar is free of dirt & debris. Rain water should fall through the <br /> pea gravel surrounding sump collar and drain into the environment. Dirt & debris allow water to puddle & <br /> rise over the sump collar into the sump. <br /> Technician placed sensor into ottom of sump saddle. <br /> "�t O at <br /> s CP S�Ullp, <br /> ALL EH STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> n R Tits: <br /> EHD 2A-'Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.